Printed Contrast Signal (Pcs); Minimum Resolution; Wide Bar Code - Opticon OPC-3301n Specification Manual

Handheld bluetooth 1d ccd scanner
Table of Contents

Advertisement

8.3. Printed Contrast Signal (PCS)

0.3 or higher
<Conditions>
MRD
: 32% and higher
(70% or higher reflectivity of space and quiet zone)
Distance
: 72 mm from the front edge of the scanner
Bar code
: JAN (resolution 0.26 mm, PCS 0.3) specified in Section 8.1.
MRD = Minimum reflectance of white space - Maximum reflectance of black bar
Reflectance of white spece - Reflectance of black bar
PCS =
Reflectance of white space
* Be sure to keep the optical window clean without dirt or scratches, or it may have a bad effect on
the reading characteristics.

8.4. Minimum Resolution

0.1 mm or more
<Conditions>
Bar code
: Code 39 (resolution 0.1 mm) specified in Section 8.1.
Distance
: 72 mm from the front edge of the scanner
Angle
: α = 0°, β = + 15°, γ = 0°
Curvature
: R = ∞

8.5. Wide Bar Code

Code 39 with width of 110 mm and resolution of 0.2 mm can be read
<Conditions>
Bar code
: Code 39 (resolution 0.20 mm, PCS 0.9) specified in Section 8.1.
Distance
: 127 mm from the front edge of the scanner
Angle
: α = 0°, β = +15°, γ = 0°
Curvature
: R = ∞
Figure 4: Wide Bar Code