C-32
MIB Parameter
(Location in Parenthesis)
*MinorAlarmThreshold
710.3.3. 8.7.4.1.1.5
(*TrafficStatisticsEntry 5)
*MajorAlarmThreshold
710.3.3. 8.7.4.1.1.6
(*TrafficStatisticsEntry 6)
*AURxPowerTest
710.3.3. 8.7.5
(*AUAlarms 5)
*AURxPowerAverageDelta
710.3.3. 8.7.5.1
(*AURxPowerTest 1)
*AURxPowerDecreaseThreshold
710.3.3. 8.7.5.2
(*AURxPowerTest 2)
*SURxPowerTest
710.3.3. 8.7.6
(*AUAlarms 6
*SURxPowerAverageDelta
710.3.3. 8.7.6.1
(*SURxPowerTest 1)
*SURxPowerDecreaseThreshold
710.3.3. 8.7.6.2
(*SURxPowerTest 2)
*RespondingSUs
710.3.3. 8.7.7
(*AUAlarms 7)
*CurrentNumberOfRespondingSUs
710.3.3. 8.7.7.1
(*RespondingSUs 1)
*AverageNumberOfRespondingSU
s
710.3.3. 8.7.7.2
(*RespondingSUs 2)
Manual Revision: 3.0
Description
Applicable to IF-based AU only.
Read-write. The threshold for
activating a minor severity alarm for
the relevant statistics type. Another
prerequisite for activating the alarm
is that the difference between the
Traffic Statistics Current Rate and
the previous Traffic Statistics
Average Rate exceeds the Traffic
Statistics Minor Alarm Minimum
Delta.
Applicable to IF-based AU only.
Read-write. The threshold for
activating a major severity alarm for
the relevant statistics type.
Applicable to IF-based AU only. AU
Alarms AU Rx Power Tests
parameters and measurement
results.
Applicable to IF-based AU only.
Read-only. The average for all SUs
that responded to the last two
polling messages of the difference
between the last RSSI at the AU
and the previous (one before last)
RSSI. (A negative value indicates
that the average RSSI was
decreased).
Applicable to IF-based AU only.
Read-write. The Minimum decrease
in the value of the AU Rx Power
Average Delta that will trigger an
alarm. (If the AU Rx Power
Decrease Threshold is +X, an alarm
will be generated if the AU Rx
Power Average Delta is smaller
than or equal to –X)
Applicable to IF-based AU only. AU
Alarms SU Rx Power Tests
parameters and measurement
results.
Applicable to IF-based AU only.
Read-only. The average for all SUs
that responded to the last two
polling messages of the difference
between the last RSSI at the SU
and the previous (one before last)
RSSI. (A negative value indicates
that the average RSSI was
decreased).
Applicable to IF-based AU only.
Read-write. The Minimum decrease
in the value of the SU Rx Power
Average Delta that will trigger an
alarm. (If the SU Rx Power
Decrease Threshold is +X, an alarm
will be generated if the SU Rx
Power Average Delta is smaller
than or equal to –X)
Applicable to IF-based AU only.
Responding SUs parameters.
Applicable to IF-based AU only.
Read-only. The number of SUs that
responded to the last polling
message.
Applicable to IF-based AU only.
Read-only. The average number of
SUs that responded to polling
message since power-up or since
the AU Alarms Option was enabled.
BreezeACCESS Version 4.3 System Manual
Values/Range
Integer
1 – 100 (%)
Integer
1 – 100 (%)
DisplayString
-99 to 99 (dBm)
Integer
1 – 99 (dBm)
DisplayString
-99 to 99 (dBm)
Integer
1 – 99 (dBm)
Integer
na (255)
Integer
na (255)