B-4
1.
From the Flash Memory Control menu select 2 - Use Current Version
After Reset.
The Use Current Version After Reset menu opens.
2.
Select 1 – Set As Default Now and press ENTER. This will actually
cause the names of the two versions to switch. The previous Shadow
version will now be called Current and vise versa. The following
message will be displayed:
UP (DOWN) Image FLASH will be operational (UP or DOWN
refers to the location in the flash memory).
The loading procedure is protected. An attempt to load an invalid
version (e.g. using <SnmpWriteCommunity>.fmr when trying to load a
new version to units with a FLASH Type: F) will be rejected.
Loading an Upgrade to a Unit
with FLASH Type: S
Use the following table to determine which source file name to use,
according to the unit's type.
X refers to the software version number, up to 5 decimal digits (e.g. for
software release 4.0.40, X=4040).
Use the SNMP write community <SnmpWriteCommunity>.fmr (default
write community is private) to define the destination filename. For
example: to load the upgrade file A3011S.SU to an SU whose IP address
is 206.25.63.55 use the following syntax:
>tftp –i 206.25.63.55 put A3011S.SU private.fmr
Manual Revision: 3.0
Unit Type
AU
SU
SU with Voice
GU
BreezeACCESS Version 4.3 System Manual
File Name
AXS.BS
AXS.SU
AXS.SUV
AXS.GU