Alvarion BreezeACCESS II System Manual page 170

Version 4.3
Hide thumbs Also See for BreezeACCESS II:
Table of Contents

Advertisement

2-34
The default parameters for these alarms is as follows:
Retransmission Minor Alarm Minimum Delta
Retransmission Minor Alarm Threshold
Retransmission Major Alarm Threshold
Dropped Frames Minor Alarm Minimum Delta
Dropped Frames Minor Alarm Threshold
Dropped Frames Major Alarm Threshold
CRC Error Minor Alarm Minimum Delta
CRC Error Minor Alarm Threshold
CRC Error Major Alarm Threshold
Duplicate Frames Minor Alarm Minimum Delta
Duplicate Frames Minor Alarm Threshold
Duplicate Frames Major Alarm Threshold
NOTE:
The value of the Major Alarm Threshold must be higher than the applicable
Minor Alarm Threshold. The system will not accept a Major Alarm Threshold
that is lower than the current Minor Alarm Threshold, and vice versa.
Show Traffic Statistics Parameters and Data - Displays for each
statistics type the configured parameters as well as the
applicable Current and Average Rates.
SU Rx Power Test - A sub menu that includes the following
options:
SU Rx Power Decrease Threshold - The minimum inverse
(negative) value of the SU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dBm).
Default value: 15 (dBm).
Show SU Rx Power Test Parameters and Data - Displays the
value of the SU Rx Power Decrease Threshold and the current
SU Rx Power Average Delta.
AU Rx Power Test - A sub menu that includes the following
options:
AU Rx Power Decrease Threshold- The minimum inverse
(negative) value of the AU Rx Power Average Delta that will
trigger an alarm.
Valid values: 1 to 99 (dBm).
Manual Revision: 3.0
BreezeACCESS Version 4.3 Operations and Administration
Parameter
Default (%)
20
30
60
10
10
20
20
40
70
5
5
15