Menus and Parameters
Power Control Parameters
The power control parameters enable to optimize the performance of the
system through controlling the transmitted power level of
BreezeACCESS units. The transmitted power level of the unit should be
decreased from the maximum level that is supported by the unit in the
following cases:
In a Subscriber Unit that is relatively close to the Access Unit, in
order to minimize the interference to signals received by the AU from
other subscriber units as well as interference to neighboring cells.
In an Access Unit typically the maximum supported transmit power
is used to enable maximum coverage. However, there may be a need
to decrease the transmitted power level in order to support relatively
small cells and to minimize the interference with the operation of
neighboring cells.
If required for compliance with local regulations or other restrictions
related to maximum allowable transmitted power.
In addition to the ability to set the transmit power to a certain fixed
level, IF-Based units (SU-A/E, AU-BS and AU-NI) support an
Automatic Transmit Power Control (ATPC) algorithm. The ATPC
algorithm automatically adjusts the power level transmitted by each SU
according to the actual level at which it is received by the AU. To
support proper operation of the system with optimal performance and
minimum interference between neighboring sectors, the ATPC algorithm
should be enabled in all units.
The algorithm is controlled by the AU that calculates for each received
frame the average RSSI at which it receives transmissions from the
specific SU. The average calculation takes into account the previous
calculated average, thus reducing the effect of short temporary changes
in link conditions. The weight of history (the previous value) in the
formula used for calculating the average RSSI is determined by a
configurable parameter. In addition, the higher the time that has passed
since last calculation, the lower is the impact of history on the
calculated average. If the average RSSI is not in the optimal range
(typically between -74dBm to -64dBm), the AU transmits to the SU a
power-up or a power-down message. The target is that each SU will be
page 2-48). An AU whose associations load status is full
cannot be selected as the Best AU, even if its' computed
mark is the highest.
ESSID – The ESSID of the AU
In addition to the neighboring AU data table, the following
information is displayed:
Best AU Support
Preferred AU MAC Address
Number of Scanning Attempts
Associated AU MAC Address (the MAC address of the
selected AU)
Run Time ESSID (the ESSID of the selected AU).