Component Identification - Graco 24N468 Instructions Manual

Lubrication controller for glc 2200
Hide thumbs Also See for 24N468:
Table of Contents

Advertisement

Component Identification

Component Identification
Keypad, Display, and Icons
NOTICE
To prevent damage to soft key buttons, do not press
the buttons with sharp objects such as pens, plastic
cards, or fingernails.
A
F
!
J
F
. 1
IG
Pump ON LEDs (A, B, C)
Pressure Control LED: In RUN MODE illuminates
A
indicating function mode that is currently running.
Cycle Control LED: In RUN MODE illuminates
B
indicating function mode that is currently running.
Time Control LED: In RUN MODE illuminates
C
indicating function mode that is currently running.
Pump OFF LED (D)
In RUN MODE this LED illuminates when in the
OFF or RESET portion of the RUN CYCLE.
4
B
C
D
E
G
H
Display (E)
A blinking field on the display indicates that the
controller is in SETUP MODE.
In RUN MODE the numbers on the display will not
blink.
Alarm LED (F)
Illuminates when any alarm is detected. When an
alarm is active, an error code displays and an
audible alarm also sounds.
RIGHT Direction Arrow/ MANUAL RUN /
ENTER (G)
In SETUP MODE: saves entry, moves cursor in
display one field to the right or to the next setup
step.
In RUN MODE: activates the pump for one complete
ON cycle if actuated during the OFF portion of the
RUN cycle.
UP and DOWN Direction Arrows (H)
Press and hold both the UP and DOWN arrow keys
together for 3 seconds to enter SETUP MODE.
In SETUP MODE: increases or decreases the
number values associated with the various RUN
MODES.
LEFT Direction Arrow / RESET (J)
In SETUP MODE: moves cursor in display one field
to the left.
In RUN MODE: pressing RESET starts a PUMP
OFF cycle.
In ALARM MODE: press once to clear buzzer, press
and hold for 3 seconds to clear warning and switch
controller to OFF MODE.
3A2960G

Advertisement

Table of Contents
loading

Table of Contents