Component Identification
Keypad, Display, and Icons
NOTICE
To prevent damage to soft key buttons, do not press
the buttons with sharp objects such as pens, plastic
cards, or fingernails.
F
F
. 1
IG
Pump ON LEDs (A)
•
Time Control LED: In RUN MODE illuminates
indicating function mode that is currently run-
ning.
Pump OFF LED (B)
•
In RUN MODE this LED illuminates when in the
OFF or RESET portion of the RUN CYCLE.
Display (C)
•
A blinking field on the display indicates the con-
troller is in SETUP MODE.
•
In RUN MODE numbers on the display will not
blink.
334662B
A
B
C
D
E
RIGHT Direction Arrow / TEST / ENTER (D)
•
In SETUP MODE, saves entry, moves cursor in
display one field to the right or to the next setup
step.
•
In RUN MODE activates the pump for one com-
plete ON cycle if actuated during the OFF por-
tion of the RUN cycle.
UP and DOWN Direction Arrows (E)
•
Press and hold both the UP and DOWN Arrow
keys together for 3 seconds to enter SETUP
MODE.
•
In SETUP MODE increase or decrease number
values associated with operation.
LEFT Direction Arrow / TEST / RESET (F)
•
In SETUP MODE moves cursor in display one
field to the left.
•
In RUN MODE, Pressing RESET starts a PUMP
OFF cycle.
•
Press and hold left and right direction arrow
together for 3 seconds to enter TEST MODE.