Advanced Programming (Series E or later models only)
A1 - Setting Up PIN Code
A PIN Code can be programmed into the GLC 2200 to
protect the settings from inadvertently being changed by
unauthorized users.
Four zeros on the display
lights, indicating you have
entered the PIN MODE.
3. The word A1:OF
appears in the display.
Press the UP or DOWN arrow button to change this
to A1:ON.
4. The cursor is automatically positioned to entered
the first character of the PIN Code. Use the UP and
DOWN arrow buttons to move up and down through
the numbers 0 to 9 until the first number in the PIN
code is displayed in the field.
5. Press the ENTER button to set the
number. The cursor automatically
moves to the next number field.
6. Repeat steps 4 and 5 for each PIN Code prompt
field.
7. Press the ENTER button to set the PIN Code and
exit Advanced Setup.
A2 - Pulsed Setup
Programs ON and OFF time in MM: SS (minutes and
seconds) for pump operation during a normal pump on
cycle.
1. To set the ON time use the UP or
DOWN arrow button to scroll through
numerals 0 to 9 until the desired
number appears in the first MM
(minutes) field.
2. Press the ENTER button to set the
number. The cursor automatically
moves to the next number field.
3. Repeat Steps 1 and 2 until all MM:SS fields are
programmed.
4. Repeat Steps 1 to 3 to program the OFF time.
22
NOTE: If the pulse mode is enabled, the pump ON LED
will blink for the duration of the pulse ON time while the
pump is on in RUN MODE. The pump ON LED will
remain solid during the RUN MODE for the duration of
the pulse OFF time.
A3 - Auxiliary Output Setup
Allows the use of the alarm output during normal pump
ON cycle.
1. The word A3:ON appears in the display.
Press the UP or DOWN arrow button to
cycle between A3:ON and A3:OF.
2. Press the ENTER button to save
and exit setup.
When the Auxiliary Output is
enabled, the output will remain
powered during the Pump ON cycle whether or not
the main pump output is pulsing.
When the Auxiliary Output is not enabled (OFF) the
alarm output will operate as an alarm output.

Series F and Later

A4 - Low Level Reset Upon Power ON
Resets the low level fault upon a power reset.
Selecting Advanced Setup Options
1. The word A4:ON appears in the
display. Press the UP or DOWN arrow
button to cycle between A4:ON and
A4:OF.
2. Press the ENTER button to save and
exit SETUP.
When the Low Level Reset is enabled
(ON), the Low Level Alarm will reset upon a power
cycle.
When the Low Level Reset is not enabled (OF), the
Low Level Alarm continues to be active upon a
power cycle.