Electrical Connections; Recommendations; Recommended Cable Cross Section - Baxi POWER HT+ Series Installation And Service Manual

Gas fired floor-standing condensing boiler
Hide thumbs Also See for POWER HT+ Series:
Table of Contents

Advertisement

6 Installation
Fig.51
Flexible flue gas system B23p
L1
L2
Fig.52
Rigid flue gas system B23p
L1
L3
L2
Fig.53
Through-roof flue gas system B23p
L1
L3
L2
6 6 .6

Electrical connections

48
L3

6.6.1 Recommendations

Earth the appliance before making any electrical connections.
Only qualified engineers may carry out electrical connections, always
with the power off.
Power the appliance via a circuit that includes an omnipolar switch with
contact opening distance of 3 mm or more.
When making electrical connections to the mains, respect the polarities.
Danger
Position the various electrical cables in such a way that they never
touch the heating pipes.
Keep the various electrical cables far enough from the heating
pipes so that they cannot be damaged by the effect of the heat.

6.6.2 Recommended cable cross section

The cable will be carefully chosen according to the following information:
Distance of the appliance from the power source.
Upstream protection.
7609474 - v02 - 04092014