User Manual
PT-SP-HD116DA
6.2 RS232 Communication Commands
Communication protocol: RS232 Communication Protocol
Baud rate: 9600
Note:
All commands need to be ended with "<CR><LF>".
In the commands, "["and "]" are symbols for easy reading and do not need to be typed in
actual operation.
Type the command carefully, it is case-sensitive.
6.2.1 System Commands
Command
>GetFirewareVersion
>SetFactoryReset
>SetReboot
>SetHelp [Param]
Data bit: 8
Description
Get firmware version.
Reset to factory default.
System reboot.
Get the command details.
[Param]= Any command.
Stop bit: 1
17
Parity bit: none
Command Example and
Feedback
<V1.0.0
<FactoryReset_True
<Reboot_EN
>SetHelp
SetHdcpActiveMode
<Set the HDCP bypass from
SRC or SINK
>SetHdcpActiveMode Param
Param = Src,Sink
Src - Active by src
Sink - Active by Sink
Need help?
Do you have a question about the PT-SP-HD116DA and is the answer not in the manual?