Hub-3000 Igmp Querier Settings - Furuno FMD-3100 Instruction Manual

Ecdis setting and adjustments for pcu-3010
Hide thumbs Also See for FMD-3100:
Table of Contents

Advertisement

3.
HUB-3000 IGMP QUERIER
SETTINGS
When constructing a network with two or more FAR-2
the IGMP querier of the HUB-3000.
Items to prepare
• PC with RS-232C serial port (with D-SUB9 pin connections)
• RS-232C serial crossover cable (with D-SUB9 pin connections)
• Software to control a serial device (HyperTerminal, TeraTerm, Putty, etc.)
Note: This manual uses TeraTerm in the explanations and procedure which follow.
RS-232C crossover cable
Pin locations (Female)
Procedure
1. Connect the RS-232C serial cable to the PC serial port.
2. Connect the loose end of the RS-232C serial cable to the HUB-3000 serial port.
Note: When removing the serial cable, disconnect the HUB-3000 first, then
disconnect the PC.
3. Start the TeraTerm application on the PC.
4. Click the [Serial Port] radio button, then select the connected COM port from the
drop-down menu.
Pin No.
Signal
1
NC
2
RD
3
SD
4
NC
5
SG
6
NC
7
NC
8
NC
9
NC
Shell
FG
COM1: Serial port (COM1)
7 radars via HUB-3000, set
Connection
3-1