[Source]: Select the data source of [Heading] or [Other].
[Source (sub)]: Set the other data source in the same range as the data of [Head-
ing]. The [Source (sub)] appears only when the source of [Other] is not entered.
[Unit]: Set the unit in the [Heading] and [Other].
[Scale
range of the upper of the graph, [Other] is for the range of the lower of the graph.
[Time Span]: Set the display range of the Y-coordinate.
[Sample Interval]: Set the interval of the graph plot.
[Scale Resolution]: Select the scale resolution of the graph.
[Change button]: Check the checkbox to show the [Change] button. Click the
[Change] button to show the [Vertical Heading Graph] hidden behind. Check the
checkbox of [Show] in [Change Button] of the component hidden behind.
[Decimal Place]: Check the checkbox to show the value after decimal point.
[Secondary (Y2) Scale]: Check the check box to show the value input from the data
source of [Secondary].
[Mathematical Sign (Scale)]: Check the checkbox to show the minus sign (-) when
the value of the X-coordinate is minus.
[Mathematical Sign (Value)]: Check the checkbox to hide the minus sign (-) when
the value above graph is minus.
1.15
The Network Transmission Setting Between
ECDIS and Radar
Connect the ECDIS and radar (FAR-2xx7/FAR-2xx8/FCR-2xx9/FAR-3xx0 series) with
the LAN cable to show the radar echo and TT symbols on the ECDIS chart display,
and show the ECDIS route and user chart symbol on the radar display.
For non-FURUNO radar, the ECDIS chart display can show the radar echo and TT
symbol on the ECDIS chart display by connecting the ECDIS and radar by serial in-
terface, using the radar connection box (RCB-002).
For FAR-2xx7, FCR-2xx9 series
Note: Confirm that the SPU board program version of the FAR-2xx7/FCR-2xx9 series
is version "03.50" or after.
1. On the SPU board of the FAR-2xx7 and FCR-2xx9 series radars, set the Dip SW
(S4) to ON.
2. To connect two antenna units, change the antenna number of second antenna
unit to [2] and set the IP address and subnet mask as shown below.
IP address: 192.168.031.102
Subnet mask: 255.255.255.0
3. Do one of the two procedures below according to the radar connected.
For FAR-2xx7 series
1) Press the MENU key to open the main menu.
2) Press and hold the 1 HL OFF key, then press the MENU key five times to open
the [INITIALIZE] menu.
3) Open [8. OTHERS]
4) Go back to the [INITIALIZE] menu and open [6. TT PRESET]
OUTPUT], then select [TTM], [TRUE] and [4800].
Range]: Set the display range of the X-coordinate. [Heading] is for the
[5. INS], then select [LAN].
1. INITIAL SETTINGS AND ADJUSTMENTS
[2. TT DATA