Download Print this page

Graco 244113 Instructions Manual page 7

Hvlp-turbine guns
Hide thumbs Also See for 244113:

Advertisement

6.
Connect air hose to gun and turbine.
7.
For cup gun, turn fluid control out until trigger movement is not restricted.
Caution: Turning knob too far will remove it.
For remote pressure pot, hold gun parallel to floor and adjust fluid pressure
to an 8 to 10 inch (203 to 254 mm) fluid stream.
NOTE: Heavier fluids or longer fluid hoses require greater pressures.
8.
Reduce and test catalyze all paint to manufacturer's specifications.
S If no reduction instructions are given, mix the fluid thoroughly, then gradually mix in reducer. To check
the consistency of the fluid. Remove the stir stick from the thinned paint. When the paint streaming off
the stick breaks into droplets, the first few drops should be one second apart.
S To compensate for faster drying time of turbine systems, use a reducer one step slower than used for
conventional air spray systems.
9.
Remove cup. Fill 3/4 full. DO NOT OVERFILL. Reattach and latch cup.
Setup
7
309317

Advertisement

loading

This manual is also suitable for:

244117244115244118