Note: If fluid is not atomizing properly, fluid may need to be thinned further, or a different
tip size may be used.
Swivel Tube Adjustment
The adjustable swivel tube allows the HVLP–Turbine Gun to be held in any position why spraying. To adjust the
position of the tube in the cup:
1. Loosen the nut (A) with a wrench (42).
2. Rotate the cup to the desired spray position.
3. Retighten the nut (A) with a wrench (42).
A
Swivel tube positioned
for spraying DOWN
10
309317
17.
To control over–spray, reduce air flow or reduce fluid volume.
cup
swivel tube
A
swivel tube
Swivel tube positioned
for spraying UP