Technical Data; Measurement Functions; Engine Test; Multimeter - Bosch FSA 740 Original Instructions Manual

Vehicle system analysis
Hide thumbs Also See for FSA 740:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
en
30 | FSA 740 |
8.

Technical data

8.1

Measurement functions

8.1.1

Engine test

Measurement functions
Rotational speed
Oil.temp
U-Battery
U-Term. 15
U-Term. 1
Ignition voltage,
spark voltage
Spark duration
Relative compression over starter current 0 – 200 Ass
U-Alternator ripple
I starter
I-Alternator
I-Glow plugs
I-Primary
Dwell angle
Dwell period
Ignition point,
Ignition timing with stroboscope lamp
Start of delivery, injection timing
Injection timing with stroboscope lamp
Pressure (atmospheric)
Duty cycle t-/T
Injection time
Pre-heating time
8.1.2

Multimeter

Measurement functions
Rotational speed
U-Battery
U-Term. 15
U-DC/ACpeak
(min./max.)
I-1000 A
I-30 A
Resistance
(R-Multi 1)
Pressure P-Air
Oil.temp
Air temperature
Liquid pressure
The measuring range is bigger than the permitted input voltage
1)
1 689 989 400
|
2019-04-01
Measuring ranges
Resolution
450 rpm – 6000 rpm
10 rpm
100 rpm – 12000 rpm
10 rpm
250 rpm – 7200 rpm
10 rpm
100 rpm – 500 rpm
10 rpm
-20 °C – 150 °C
0.1 °C
0 – 60 V
0.1 V
0 – 60 V
0.1 V
0 – 20 V
50 mV
±500 V
1 V
±50 kV
100 V
0 – 6 ms
0.01 ms
0.1 A
0 – 200%
0.1%
0 – 1000 A
0.1 A
0 – 30 A
0.1 A
0 – 100%
0.1%
0 – 360°
0.1°
0 – 50 ms
0.01 ms
0.1 ms
0 – 60 KW
0.1 KW
0 – 60 KW
0.1 KW
-800 hPa – 1500 hPa
1 mbar
0 – 100%
0.1%
0 – 25 ms
0.01 ms
0 – 20 ms
0.01 ms
Measuring ranges
Resolution
As with the engine test
0 - 60 V
0.01 V
0 - 60 V
0.1 V
1)
±200 mV – ±20 V
0.001 V
±20 V – ±200 V
0.01 V
1)
±1000 A
0.1 A
±30 A
0.01 A
0 – 1000 Ω
0.001 Ω
1 kΩ – 10 kΩ
0.1 Ω
10 kΩ – 999 kΩ
100 Ω
0.2 hPa – 2500 hPa
0.1 hPa
-20 °C – 150 °C
0.1 °C
-20 °C – 100 °C
0.1 °C
0 – 10000 hPa
10 hPa
Sensors
B+/B– battery cable
Clip-on sensor, secondary measuring sensor,
primary connection cable (UNI 4)
30 A amps clamp, diesel clip-on sensor
1000 A amps clamp (starter current)
Oil temperature sensor
Battery connection cable B+/B–
Primary connection cable (UNI 4)
Primary connection cable (UNI 4)
Primary connection cable (UNI 4),
Secondary measuring sensor
Primary connection cable (UNI 4),
Secondary measuring sensor
Primary connection cable (UNI 4),
Secondary measuring sensor
CH1 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
Primary connection cable (UNI 4)
Secondary measuring sensor
Amps clamp 30 A
Clip-on sensor
Clip-on sensor
Atmospheric pressure sensor
CH1/CH2 multi measurement cable
CH1/CH2 multi measurement cable
CH1/CH2 Multi measurement cable
Sensors
Battery connection cable B+/B–
Primary connection cable (UNI 4)
CH1/CH2 multi measurement cable
Amps clamp 1000 A
Amps clamp 30 A
CH1 multi measurement cable
Atmospheric pressure sensor
Oil temperature sensor
Air temperature sensor
Liquid pressure sensor
Oil pressure sensor
Robert Bosch GmbH

Hide quick links: