8.

Technical data

8.1

Measuring functions

8.1.1

Engine test

Measuring functions
Speed
Oil temperature
U‑battery
U terminal 15
U terminal 1
Ignition voltage,
Spark voltage
Spark duration
Relative compression via starter current
U alternator ripple
I starter
I Alternator
I Spark plugs
I Primary
Closing angle
Closing time
Ignition point,
Ignition advance with stroboscope
Start of delivery, Start of injection,
Injection timing
with stroboscope
Pressure (air)
Pulse‑duty factor t‑/T
Injection time
Glow time
8.1.2

Multimeter

Measuring functions
Speed
U battery
U term. 15
U‑DC
min./max.
I‑1000 A
I‑30 A
Resistance
(R Multi 1)
Pressure P‑air
Oil temperature
Air temperature
Fluid pressure
The measuring range is greater than the permissible measurement voltage
1)
Robert Bosch GmbH
Measuring ranges
Resolution
450 min
– 6000 min
10 min
‑1
‑1
100 min
– 12000 min
10 min
‑1
‑1
250 min
– 7200 min
10 min
‑1
‑1
100 min
– 500 min
10 min
‑1
‑1
‑20 °C – 150 °C
0,1 °C
0 – 60 V
0,1 V
0 – 60 V
0,1 V
0 – 20 V
50 mV
±500 V
1 V
±50 kV
100 V
0 – 6 ms
0,01 ms
0 – 200 Ass
0,1 A
0 – 200 %
0,1 %
0 – 1000 A
0,1 A
0 – 30 A
0,1 A
0 – 100 %
0,1 %
0 — 360 °
0.1 °
0 – 50 ms
0,01 ms
0,1 ms
0 – 60 °KW
0,1 °KW
0 – 60 °KW
0,1 °KW
‑800 hPa – 1500 hPa
1 mbar
0 – 100 %
0,1 %
0 – 25 ms
0,01 ms
0 – 20 ms
0,01 ms
Measuring ranges
Resolution
as for engine test
0 ‑ 60 V
0,01 V
0 – 60 V DC
0,1 V
1)
±200 mV – ±20 V
0,001 V
0,01 V
±20 V – ±200 V
1)
±1000 A
0,1 A
±30 A
0,01 A
0 – 1000 Ω
0,001 Ω
1 kΩ – 10 kΩ
0,1 Ω
10 kΩ – 999 kΩ
100 Ω
0,2 hPa – 2500 hPa
0,1 hPa
‑20 °C – 150 °C
0,1 °C
‑20 °C – 100 °C
0,1 °C
0 – 10000 hPa
10 hPa
Technical data | FSA 760 Edition | 27
Sensors
Connecting cable B+/B–
‑1
Trigger clamp, Secondary sensor,
‑1
Primary connecting cable (UNI 4)
Current clamp 30A, Diesel clip‑on sensor,
‑1
Current clamp 1000 A (starter current)
‑1
Oil temperature sensor
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4)
Primary connecting cable (UNI 4),
Secondary sensor
Primary connecting cable (UNI 4),
Secondary sensor
Primary connecting cable (UNI 4),
Secondary sensor
Multi measuring cable CH1
Current clamp 1000 A
Current clamp 30 A
Primary connecting cable (UNI 4)
Secondary sensor
Current clamp 30 A
Trigger clamp
Clip‑on sensor
Air pressure sensor
Multi measuring cable CH1 / CH2
Multi measuring cable CH1 / CH2
Multi measuring cable CH1 / CH2
Sensors
Connecting cable B+/B–
Primary connecting cable (UNI 4)
Multi measuring cable CH1 / CH2
Current clamp 1000 A
Current clamp 30 A
Multi measuring cable CH1
Air pressure sensor
Oil temperature sensor
Air temperature sensor
Fluid pressure sensor,
Oil pressure sensor
1 689 989 298