32 | FSA 740 |
8.1.5

Oscilloscope measurement functions

Measurement
Measuring
functions
range
1)
Secondary voltage 5 kV – 50 kV
Primary voltage
20 V – 500 V
Voltage
200 mV –
200 V
2)
5 V – 500 V
AC coupling
200 mV – 5 V
Power
2 A, 5 A, 10 A,
20 A, 30 A
Power
50 A, 100 A,
200 A, 1000 A
The measuring range is positive or negative depending on the
1)
base line.
The measuring range is greater than the permissible
2)
measurement voltage
8.1.6

Oscilloscope functions and specifications

Function
Input coupling CH1/CH2
Input impedance CH1/CH2
(ground-related)
Input impedance CH1/CH2
(galvanically isolated)
Input impedance CH2
(differential)
Bandwidth CH1
(galvanically isolated)
Bandwidth CH1 (relative to
ground)
Bandwidth CH2 (relative to
ground)
Bandwidth
Measurement cable with voltage
splitter
CH2 bandwidth
(differential measurement)
Bandwidth 1000 A amps clamp
Bandwidth 30 A amps clamp
Bandwidth of secondary
measuring sensor
Bandwidth
Primary connection cable (UNI 4)
Time ranges
(related to 500 sensing points)
Time ranges
(related to 1 sensing point)
Time base accuracy
Vertical accuracy
Device without sensors
Vertical resolution
Memory depth
Scan rate per channel
1 689 989 400
|
2019-04-01
Sensors
Secondary measuring
2)
sensor
Primary connection cable
2)
(UNI 4)
Multi-measurement cable
CH1 / CH2
Measurement cable with
2)
voltage splitter
Battery connection cable
B+/B–
Amps clamp 30 A
Amps clamp 1000 A
Specification
AC/DC
1 MOhm
1 MOhm (5 – 200 V)
10 MOhm (200 mV — 2 V)
4 MOhm
> 5 kHz = 200 mV – 2 V
> 25 kHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
> 500 kHz
> 30 kHz
> 1 kHz
> 50 kHz
> 1 MHz
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
10 µs – 100 s
20 ns – 200 ms
0.01%
±2% of measured value
±0.3% of measuring range
(Offset error for ranges
> 1 V) or ±5 mV (offset error
for ranges 200 mV – 1 V)
10 bit
1 Mega scan values or
50 curves
50 Ms/s
8.2

Signal generator

Function
Specification
Amplitude
-10 V – 12 V
(load < 10 mA) to ground
Signal forms
DC, sinusoidal, triangular, square-
wave
Frequency range
1 Hz – 1 kHz
output current
30 mA – 75 mA
(load-dependent)
Impedance
Approx. 60 Ohms
Symmetry
10% – 90%
(triangle, rectangle)
Curve generation
Output rate up to 100000 values/s,
8 bit resolution, Y full range is
adjustable( bit), unipolar / bipolar
operation
Short-circuit resistance
< 50 V static
to interference voltage
Short-circuit resistance
< 500 V/1 ms dynamic
to interference voltage
R
Automatically engaged filters and damping members
to improve signal quality.
R
Automatic shut-off in the case of short circuit,
detection of interference voltage on starting signal
generator.
Robert Bosch GmbH