24 | FSA 740 |
3.4.3

Rear view FSA 740

5
4
3
2
1
Fig. 2:
Back view FSA 740
1 Exhaust gas sampling probe (diesel vehicle)
2 BEA 070
*)
3 Mains plug
4 BEA 040
*)
5 Mounting bracket 1 681 332 332 (special accessory)
6 Exhaust gas sampling probe (gasoline vehicle)
7 BEA 055
*)
sometimes included in special accessories
*)
3.4.4

Multiple socket outlet

The power strip is designed for the nominal
voltage of 240 V AC and the rated current of
13 A. These values must not be exceeded.
3.4.5

Electronic ballast

The electronic ballast is installed between the power
supply cable and the socket strip. This limits the
engagement current to the components connected to
the socket strip and prevents the workshop failsafe from
cutting in.
1 689 989 400
|
2019-04-01
3.4.6
6
1
Fig. 3:
1 Temperature sensor
2 B+/B– battery connection cable
7
3 Primary adapter cable (UNI 4)
4 Clip-on sensor or
Adapter cable 1 684 465 513 for clip-on sensor
5 RS 232 serial interface (no function)
6 Sensor KV–
7 USB port for data connection PC
8 Sensor KV+
9 Voltage supply for measuring unit (power supply unit)
10 CH1 multi measurement cable or measurement cable with
voltage divider or amps clamp 30 A
11 CH2 multi measurement cable or measurement cable with
*)
voltage divider or amps clamp 30 A or amps clamp 1000 A
12 Timing light
13 Air pressure measurement
14 Liquid pressure sensor
During engine speed measurements with a clip-on sensor, always
*)
*)
connect adapter cable 1 684 465 513 between port FSA 740 and
the clip-on sensor connection cables.
3.4.7
The measurement cable with voltage divider
(1 687 224 300) is used for voltage measurements
up to 60 VDC/30 VAC/300 VACpeak. For the
measurement cable with voltage splitter, the test
prods (1 684 485 434/. 435) in accessory (1 687 016
118) and alligator clips (1 684 480 403/. 404) are
provided as measurement accessories. Never use the
measurement cable with voltage divider to measure
mains or similar voltages.

Connection panel FSA 740

DANGER – Risk of electric shock from
excessively high measurement voltage!
The measurement of voltages in excess of
60 VDC/30 VAC/42 VACpeak using CH1 /
CH2 multi measurement cable will result in
injury, heart failure or fatal electric shocks.
Never use CH1 / CH2 multi measurement
cable to measure mains or similar
voltages.
KV-
KV+
CH1
15V DC
COM
USB
15+
- 1
3
5 6 7 8 9 10 11 12 13 14
2
4
Connection panel FSA 740 (viewed from underneath)

Measurement cable with voltage divider

D
X
CH2
45977541-Ko
*)
Robert Bosch GmbH

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents