3.1 Install the FLIR DNA tool
The FLIR Discovery Network Assistant (DNA) tool does not require a license to
use and it is free. Download it from
FLIR.com > Products > Security > Visible Security
computer running Windows on the same VLAN to which you will connect the
camera. Then, unzip the file.
3.2 Connect the Camera
a. Attach an Ethernet cable from the
network switch to the RJ45 connector for
a 10/100/1000 Mbps Ethernet and PoE+
(Power over Ethernet) IEEE 802.3at
connection. Ethernet is required for
streaming video and for configuring the
camera.
b. Connect the audio and alarm connectors,
if needed.
c. If using an external DC or AC power
supply, connect its wires to the two-pin
terminal block. Then, attach the terminal
block to the system cable's two-pin power
connector.
e. (Optional) Insert a microSD card into the slot on the camera body. For
information about accessing the microSD card slot and the camera's other
internal interfaces, see the camera's installation and user guide.
3.3 Configure for Networking
You can configure the camera using version 2.3.0.20 or higher of the DNA tool,
the camera's web page, or a supported VMS.
Discover camera IP address
Configure IP address, mask, and gateway
Configure DNS settings, MTU, and Ethernet speed
Change user credentials
CB-6404/CB-6408 QIG Rev 100
Task
This document does not contain any export-controlled information.
the FLIR Quasar™ Premium Bullet pages at
Cameras. Save the ZIP file on a
System Cable
1 Black
2
3
DNA tool
Connector
RJ-45
Black
12 VDC/24 VAC -
Red
12 VDC/24 VAC+
Yellow
AUDIO IN+
Orange
AUDIO IN-
Purple
AUDIO OUT+
Green
AUDIO OUT-
Red
ALARM IN Signal
Black
ALARM IN GND
Brown
ALARM OUT Signal
Blue
ALARM OUT COM