Appendix 6: Mcd904 Wiring Instructions - Adtech TV5600-B01 Series User Manual

Dispensing control system
Table of Contents

Advertisement

User Manual of TV5600-B01 Series Dispensing Control System

Appendix 6: MCD904 Wiring Instructions

1. Input port wiring instructions
1.01 Common input ports
SENSER
INPUT
+24V
Input common (+24V power supply)
0
Xhome
1
Yhome
GND
Internal 24V power ground
+24V
Input common (+24V power supply)
2
Z home
3
R home
GND
Internal 24V power ground
+24V
Input common (+24V power supply)
4
Xtravel limit
5
Ytravel limit
GND
Internal 24V power ground
+24V
Input common (+24V power supply)
6
Ztravel limit
Function
103
KEY
Function
INPUT
GND
Internal 24V power ground
8
Custom
9
Custom
10
Custom
11
Custom
GND
Internal 24V power ground
GND
Internal 24V power ground
Start,
system
12
required
Emergency
13
configurationand modification
Reset, allow configurationand
14
modification
Pause,
system
15
required
GND
Internal 24V power ground
configuration
stop,
allow
configuration

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents