Z-Axis Height Adjustment; 03Batch Deleting; Batch Editing - Adtech TV5600-B01 Series User Manual

Dispensing control system
Table of Contents

Advertisement

6.04.02 Z-axis height adjustment

This function is mainly used to uniformly adjust the Z-axis coordinates of the graph. First
determine the start point of the graph, and then move the Z axis to the desired coordinate
position. After calling this function, the Z coordinates of the entire graph will be adjusted
according to the value of the current Z coordinates. (When using this function, please note that
the needle height after offset should not exceed the limit, or else it will not operate normally and
will produce an overrun error). (The Z-axis height adjustment is used in the same way as the
graphic translation).

6.04.03Batch deleting

First select the range of machining points that need to be deleted, and press [F1] to delete.

6.04.04 Batch editing

The batch edit function is mainly used to modify a large amount of data.
Range: Start machining point number and end machining point number to be modified
Content: Select the content that needs to be modified
Condition: Specify that the data to be modified is equal to, not equal to, greater than or
less than a specified value.
Method: Three methods are available: Set value, set increment, and set ratio. Setting
value is to directly set the specified value to the content to be modified; setting
increment is to add a value to the original value (decrease if the specified increment is
negative); setting ratiois to multiplythe original value by a value.