HC05EVS Configuration and Operation
Interrupt Mask
Control Switch,
SW1
36
The eight positions of switch SW1 enable or disable the port A interrupt
mask options. Each position controls one port A line. A switch in the left
position, OFF, disables the option; a switch in the right position, ON,
enables the option.
If a mask option is enabled (switched ON) and the corresponding bit of
the port A data direction register is configured as an input, a low on the
port A pin generates an interrupt. This diagram shows a possible setting.
Interrupt masks are disabled for port A lines 0 through 3 and are enabled
for port A lines 4 through 7.
The default setting for all eight positions of SW1 is OFF.
HC05EVS Configuration and Operation
Setting M68EM05P18 Jumper Headers
SW1
PA0
PA7
ON
PORT A MASK
OPTION PULLUPS
M68EM05P18UM/D
MOTOROLA