Distributed Expansion - Bosch CL300 Manual

Hide thumbs Also See for CL300:
Table of Contents

Advertisement

Configuration
2.1.12.3

Distributed Expansion

Expansion line
2−24
Distributed expansion ensures communication between the GS301/ 301−K Basic
Station and several remote EWS300 Expansion Stations.
Maximum distance from the basic station to the farthest expansion station is 800 m.
Distributed expansion in its maximum configuration includes one basic station (1 x
GG301/301−K and 2 x EG300) and 4 x 2 EWS300 Expansion Stations, connected to
the distributed expansion station in GG301/301−K and forming two lines. The dis
tance between the individual sections can be up to 200 m. Expansion module slots
are detailed in paragraphs 2.1.12.4 and 2.1.12.5. The illustration below shows the
arrangement of distributed expansion, using a GG301 Basic Unit.
AG/Z
EG300
AG/Z
EG300
AG/DU
EG300
AG/P
Max. possible configuration using
AG/DU = 4 x as shown
Fig. 2−13 Distributed Expansion
AG/Z
EG300
AG/Z
EG300
AG/DZ
AG/P
GG301
200 m max.
AG/P
200 m max.
Flexible Automation
Expansion line
AG/Z
EG300
AG/Z
EG300
AG/DU
EG300