Bosch CL300 Manual page 97

Hide thumbs Also See for CL300:
Table of Contents

Advertisement

Flexible Automation
Specifications
Digital Output Modules
Nominal Voltage
Permissible Voltage Range
to DIN 19240
Number of Outputs
Nominal Current per channel
(24 V DC, 55 C)
_
Current Range
Logic "1" Level
(Max. supp. volt.)
Max. Leakage Current for "0"
Switch−on Delay
Switch−off Delay
Int. Current Consumption
(12 V)
Overload Protection:
Electronic
Thermal
Limiting of Indirect
Switch−off Volt. (typ.)
Polarity Reversal
Protection for Supp. Volt.
Simultaneity Factor
(with fan)
Short−circuit Current
Lamp Load (8 Hz)
Max. Circuit−breaker size
Width
4.4.1.1
24 V DC
20.4 V−28.8 V and 5 % Ripple factor from
32
0.2 A
0.4 ...
200 mA
(2 A)
(0.2 A)
−2.5 V
(0.5 A)
0.2 mA
450
m
s
Yes
Yes
−0.6 V
No
Fuse T 2 A
100 %
220−
500 mA
5 W
Up to 00
Fig. 4−21 Specifications of output modules (Sheet 1 of 3)
System Modules
see paragraph
4.4.1.2
4.4.1.3
24 V DC
24 V DC
superimposed AC
32
16
0.5 A
0.5 A
2 ...
1 mA ...
500 mA
0.5 A
−2.5 V
−2.5 V
0.5 mA
0.5 mA
40
m
s
350
m
s
300
m
s
2 mA per activated output
Fuse
FF 0.63 A
Yes
−15 V
−15 V
Limited
see
100 %
4.4.1.2
550−
760 mA
2 W
10 W
Up to 00
Up to 2
1 module width
4.4.1.4
4.4.1.5
24 V DC
24 V DC
16
16
0.5 A
2 A
4 mA ...
4 mA ...
2 A
2A
− 2.5 V
−2.5 V
2 mA
2 mA
300
m
s
300
m
s
FF 2.5 A
Yes
−15 V
−15 V
Limited
Fuse T 2 A
50 %
50 %
2.02−3.7 A
25 W
5 W
Up to 8
Up to 8
4−45