Maintenance
7.2
Fan Unit Filter Replacement
12
7 − Fan unit latch
8 − Filter mat latch
9 − Filter mat holder
11 − Filter mat
12 − Filter mat holder insertion slot
Procedure
7−4
The filter should be regularly inspected for contamination and be re
placed, if necessary.
Fan Unit − Front View
7
Fig. 7−1 Fan Unit − Front View
Remove fan unit as described in paragraph 2.1.8.
L
Inspect filter mat for contamination and replace it, if necessary, as
L
follows.
Turn latch (8) clockwise or counterclockwise to unlatch.
L
Loosen filter mat holder (9) and remove it from slot (12) by pulling it
L
towards the right.
Replace filter mit (11).
L
Insert filter mat holder (9) into slot (12) and close.
L
11
9
8