Software Description
Counter Remanency S14
Allocation Lists S16−S46
Bit
15
S16
0
I−Byte
15
5−18
Limiting (byte) address for counter remanency
Default
Example
;Definition of the counter remanency limit
L
W
T
W
Set allocation lists for input and output modules.
Default
Allocation
S16, S18, S20, S22
S24, S26, S28, S30
S32, S34, S36, S38
S40, S42, S44, S46
Bit 1 = Byte allocated
Bit 0 = Byte not allocated (default), no set allocation list defined
Example
;1 word input allocation in S16, input bytes 0, 1, 4, 5 are used
L
W
K0033H,B
T
W
B,S16
16−bit allocation mask
14
13
12
11
10
9
0
0
0
0
0
0
The input bytes 0, 1, 4, 5 are used.
Fig. 5−14 Allocation Lists S16−S46 (Example)
Byte 0−7 non−remanent (C0−C63)
Byte 8−15 remanent (C64−C127)
K2H,B ;C16 = 1st remanent counter
B,S14
no set allocation list defined
4 words for input allocation (I0−I63)
4 words for output allocation (O0−O63)
4 words for extended input allocation
(EI0−EI63)
4 words for extended output allocation
(EO0−EO63)
8
7
6
5
4
0
0
0
1
1
5
4
Flexible Automation
3
2
1
0
0
0
1
1
1
0

Hide quick links: