4.7 External AC Circuit Breaker and Residual Current
Device
Please install a circuit breaker to ensure the inverter is able to
disconnect from grid safely. The inverter is integrated with a RCMU,
however, an external RCD is needed to protect the system from
tripping, either type A or type B RCD are compatible with the inverter.
The integrated leakage current detector of inverter is able to detect
the real time external current leakage. When a leakage current
detected exceeds the limitation, the inverter will be disconnected
from grid quickly, if an external residual current device is connected,
the action current should be 30mA or higher.
Button
SET
Confirmation or cursor shift (when input digits)
ESC
Exit
Add
Table 4.3 Button description of three phase meter