SAJ 8000B series User Manual

SAJ 8000B series User Manual

Enhanced inverter
Table of Contents

Advertisement

8000B Series Enhanced Inverter
User Manual
Version code:8000B-E201208-1MB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8000B series and is the answer not in the manual?

Questions and answers

Summary of Contents for SAJ 8000B series

  • Page 1 8000B Series Enhanced Inverter User Manual Version code:8000B-E201208-1MB...
  • Page 2: Table Of Contents

    1.1 Description of Model………………………………………......…08 1.2 Description of Nameplate…………………………………....………08 1.3 8000B Series Inverter Table……………………………....……………09 1.4 Specifications of 8000B Series Inverter………………....…………10 1.5 Outline Drawing and Dimensions………..........……12 1.6 Selection Instruction Table of Brake Resistor and Brake Unit……..…17 Chapter 2 Mechanical and Electric Installation………….....18 2.1 Mechanical Installation………………………………….....………18...
  • Page 3 8000B Series PRECAUTION Never modify the products. Failure to observe this warning can result in electrical shock or personal injury. SAJ is not responsible for any modification of the frequency products made by the user, since that will void your guarantee.
  • Page 4: Notes For Safe Operation

    8000B Series Notes for Safe Operation Read this instruction manual thoroughly before installation, operation, maintenance or inspection of the frequency inverters. In this manual, safe operation are classified as “WARNING” or “CAUTION”. WARNING Indicate a potentially dangerous situation which, if not avoided, could result in death or serious injury to personnel.
  • Page 5 8000B Series Installation WARNING Install the frequency inver ter on nonflammable material like metal. Otherwise it may cause a fire. WARNING Make sure that the mounting environment away from metal dust. Otherwise it may cause damage to the frequency inverter.
  • Page 6 8000B Series CAUTION Never connect the AC power supply to output terminals U, V and W. Otherwise the inverter will be damaged and the guarantee is invalid. Make sure that wiring conform to EMC requirements and local power safe standard. Make sure to use right wire according to this instruction manual.
  • Page 7 8000B Series When the Power is On WARNING Do not open or remove the front cover when operation. Otherwise it may cause an electrical shock. Never touch the inverter and optional parts by wet hands. Never touch the connection terminals. Otherwise it may cause an electrical shock.
  • Page 8 8000B Series Maintenance WARNING After the main circuit power supply is OFF, make sure the charge LED is OFF when maintain or inspect. Never maintain or inspect the inverter and mechanical load when the power supply is still ON. Otherwise it may cause damage and injury.
  • Page 9: Notes For Other Important Operations

    8000B Series Notes for Other Important Operations CAUTION 1. Check Insulation of the Motor Check insulation of the motor and wire when the motor is used again after long time idle or for the first time. Disconnect the wire between the motor and the inverter before check insulation.
  • Page 10 8000B Series 7. Allowable Voltage Range and Power Supply Phase Make sure the inverter works under allowable voltage range. If necessary, use boosting transformer or step-down transformer to change the voltage of power supply. Never change the 3-phase of inverter into 2-phase. Otherwise it will cause damage to the inverter.
  • Page 11: Chapter 1 Select The Right Type

    8000B Series Chapter 1 Select the Right Type 1.1 Description of Model 1.2 Description of Nameplate ­ - ­ ­-...
  • Page 12: B Series Inverter Table

    8000B Series 1.3 8000B Series Inverter Table Power Rated Input Rated Output Motor Inverter Model capacity Current Current Capacity kW G/P Single-phase 220V±15% 8000B-2SR75GB 0.75 0.75 8000B-2S1R5GB 14.2 8000B-2S2R2GB Three-phase 380V±15% 8000B-4TR75GB 0.75 0.75 8000B-4T1R5GB 8000B-4T2R2GB 8000B-4T004GB/4T5R5PB 4/5.5 10/15 9/13 4/5.5...
  • Page 13: Specifications Of 8000B Series Inverter

    8000B Series 1.4 Specifications of 8000B Series Inverter Control Mode Sensorless vector control V/F control Start Torque 0.5Hz 150% 0.5Hz 100% Rotation Speed 1:200 1:100 Ratio Precision of Speed ±0.5% ±1.0% Regulation M o d e l G : 1 5 0 % a b o v e t h e r a t e d c u r r e n t f o r 6 0 seconds;180% above the rated current for one second.
  • Page 14 8000B Series Input Analog setting:max. frequency × 0.1%; Frequency Digital setting:0.01Hz Resolution Output Voltage 0~rated input voltage Output Frequency 0.00~600Hz Range Digital Input Six (programmable) Terminals Characteristics Analog Input AVI:0~10V; ACI:0~10V or 0/4~20mA Terminals Relay Output 1 relay output Open Collector...
  • Page 15: Outline Drawing And Dimensions

    8000B Series 16 parameters c an by displayed including r unning LED Display frequency, DC bus voltage, output voltage, output current, etc. Communication RS485 with standard MOBUS protocol. Function Other Password Four-digit password can be set and become effective Functions Setting after 1 minute.
  • Page 16 8000B Series 1.5.2 Dimensions 1.5.2.1 Dimensions Drawing 0.75kW~2.2kW (model G) 4kW~7.5kW (model G) 11kW~110kW (model G) ­ - ­ ­-...
  • Page 17 8000B Series 132kW~185kW (model G) 200kW~250kW (model G) 280kW~400kW (model G) ­ - ­ ­-...
  • Page 18 8000B Series 1.5.2.2 Dimensions Table Installation Hole Dimensions Appearance Dimensions (mm) Diameter Inverter Model (mm) (mm) 8000B-2SR75GB 8000B-2S1R5GB 142.7 151.7 126.8 ø5 8000B-2S2R2GB 8000B-4TR75GB 8000B-4T1R5GB 142.7 151.7 126.8 ø5 8000B-4T2R2GB 8000B-4T004GB/4T5R5PB 8000B-4T5R5GB/4T7R5PB 144.4 249.5 155.5 159.5 ø5.9 8000B-4T7R5GB 8000B-4T011GB/4T015PB 8000B-4T015GB/4T18R5PB 156.6 378.3...
  • Page 19 8000B Series 1.5.2.3 Dimensions of Extension Keyboard 0.75kW~2.2kW (model G) 4kW~7.5kW (model G) 11kW~400kW (model G) ­ - ­ ­-...
  • Page 20: Selection Instruction Table Of Brake Resistor And Brake Unit

    8000B Series 1.6 Selection Instruction Table of Brake Resistor and Brake Unit Recommended Recommended Inverter Model Power of Brake Resistance Value Brake Unit Resistor of Brake Resistor 8000B-2SR75GB ≥150Ω 8000B-2S1R5GB 100W ≥100Ω 8000B-2S2R2GB 100W ≥70Ω 8000B-4TR75GB 150W ≥300Ω 8000B-4T1R5GB 150W ≥220Ω...
  • Page 21: Chapter 2 Mechanical And Electric Installation

    8000B Series Chapter 2 Mechanical and Electric Installation 2.1 Mechanical Installation 2.1.1 Installation Environment The ambient temperature exerts great influences on the service life of the inverter and is not allowed to exceed the allowable temperature range (-10℃ to 40℃ ).
  • Page 22: Electric Installation

    8000B Series 2.1.3 Drawing of Moving the Front Cover 2.2 Electric Installation 2.2.1 Connecting of Peripheral Equipments ­ - ­ ­-...
  • Page 23 8000B Series 2.2.2 Recommended Table of External Electrical Parts Conducting Conducting Conducting Circuit Wire of Wire of Wire of Breaker Recommended Inverter Model Main Circuit Main Circuit Control (MCCB) Contactor (A) at the Input at the Input Circuit Side (mm...
  • Page 24 8000B Series 2.2.3 Recommended Table of Reactor AC Reactor at the AC Reactor at the DC Reactor Input Side output Side Inverter Model Voltage Current Inductance Current Inductance Current Inductance (mH) (mH) (mH) 8000B-2SR75GB 8000B-2S1R5GB 220V 8000B-2S2R2GB 8000B-4TR75GB 8000B-4T1R5GB 8000B-4T2R2GB...
  • Page 25 2. Improve the whole ef f iciency and ther mal Additional parts of stability of the inverter. DC Reactor 8000B series inverter 3. Eliminate the impact of higher harmonics at the input side on the inverter and reduce the external conduction and radiation interference.
  • Page 26: Chapter 3 Wiring

    8000B Series Chapter 3 Wiring 3.1 Standard Wiring Diagram 3.1.1 Wiring Diagram of 0.75kW~2.2kW (model G) (3-phase,380V) Note: 1. ◎ refers to terminals of main circuit; ○ refers to terminals of control circuit. 2. 0.75kW~2.2kW (model G) : brake unit is standard part inside.
  • Page 27 8000B Series 3.1.2 Wiring Diagram of 4kW~7.5kW (model G) (3-phase,380V) Note: 1. ◎­refers to terminals of main circuit; ○­refers to terminals of control circuit. 2. 4kW~7.5kW (model G) : brake unit is standard part inside. ­ - ­ ­-...
  • Page 28 3.1.3 Wiring Diagram of 11kW~18.5kW (model G) (3-phase,380V) Note: 1. ◎­refers to terminals of main circuit; ○ refers to terminals of control circuit. 2. 11kW~18.5kW (model G) : brake unit is standard part inside.
  • Page 29 8000B Series 3.1.4 Wiring Diagram of 22kW~400kW (model G) (3-phase,380V) Note: 1. ◎­refers to terminals of main circuit; ○ refers to terminals of control circuit. 2. 22kW~400kW (model G) : brake unit is additional part outside. 3. 22kW~400kW (model G) : DC reactor is additional part outside.
  • Page 30: Terminal Descriptions Of Main Circuit And Control Circuit

    8000B Series 3.2 Terminal Descriptions of Main Circuit and Control Circuit 3.2.1 Main Circuit Terminals: (1) Main circuit terminals (0.75kW~2.2kW (model G) with built-in brake unit) (2) Main circuit terminals (4kW~7.5kW (model G) with built-in brake unit) (3) Main circuit terminals (11kW~18.5kW (model G) with built-in brake unit)
  • Page 31 8000B Series Terminals Descriptions R, S, T Terminals of AC power input. U,V, W Terminals of AC power output (+), (-) Spare terminals for connecting external brake unit. Spare terminal for connecting external DC reactor. Spare terminal for connecting external brake resistor.
  • Page 32 3.2.2.5 Terminals U, V and W Capacitor device or surge absorber can not be connected to inverter output side by terminals U, V and W. Otherwise, it may cause frequent inverter protection or damage to inverter. If motor cable is too long, it may generate electrical resonance easily due to the impact of distributed capacitance and thus damage the motor insulation or generate higher leakage current to cause inverter protection.
  • Page 33 8000B Series Terminal Interface Type Function Symbol Standard 485 difference signal positive terminal 485 difference signal negative terminal Standard RS485 Computer Extension power positive terminal (+5V) communication Communication interface +15V Extension power positive terminal(+15V) Extension power negative terminal 3.2.4 Descriptions of Control Circuit Terminals...
  • Page 34 8000B Series Output range: 0~10V or 0/4-20mA. It is selected by jumper JP2 on control board. The default is current output. Analog output 1-2Pin: current output; 2-3Pin: voltage output. terminal 2 0.75~2.2kW:0/4~20mA. 4~400kW:0~10V / 0/4~20mA. TA-TB:normal open;TB-TC:normal close Contact capacity:...
  • Page 35: Chapter 4 Operation

    8000B Series Chapter 4 Operation 4.1 Keypad Description 4.1.1 Keypad Schematic Diagram 4.1.2 Key Function Description Symbol Key Name Function Description PRGM Program/ Exit key Enter or exit of menu, parameter modification P r o g r e s s i v e l y e n t e r m e n u a n d c o n f i r m Data enter key parameter.
  • Page 36: Operation Process

    8000B Series 4.1.3 Indicator Light Description Indicator Light Name Description Light on: inverter running status. STOP Light on: inverter stops or malfunction status. Lights of FWD and RUN are on at the same time: inverter forward running status. Lights of REV and RUN are on at the same time: inverter reversely running status.
  • Page 37 8000B Series Under the third-class menu, if the parameter has no flickering bit, it means that the function code cannot be modified. The possible reasons include: (1) The parameter of this function code can’t be modified, such as actually detected parameter, operation records and so on.
  • Page 38 8000B Series of motor stator resistor, rotator resistor and leakage inductance, while the parameters of motor mutual inductance and no-load current are not detected. The parameters of motor mutual inductance and no-load current can be calculated by the following formula:...
  • Page 39: Chapter 5 Function Code Table

    8000B Series Chapter 5 Function Code Table Notice: “○”: The parameters can be modified at stop or running status. “◎”: The parameters cannot be modified at running status. “●”: The parameters which are actual-detecting record value cannot be modified. Modifi-...
  • Page 40 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Range of 0 : R e l a t i v e t o t h e m a x i . auxiliary frequency F0.05 ● frequency...
  • Page 41 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type 0 : R u n n i n g a t l o w e r l i m i t The function frequency F0.15 of lower limit ○...
  • Page 42 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Cooling fan running method 0: Keep running when power on F0.25 (only for 4kW ○ 1: Automatic running and above inverter) F1 Group: Start and Stop Parameters 0:Start directly F1.00...
  • Page 43 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F1.09 DC braking time 0.0~50.0s 0.1s 0.0s ○ Dead time F1.10 between FWD 0.0~3600.0s 0.1s 0.0s ○ and REV Terminals 0: Disabled F1.11 enable option ○ 1: Enabled when power on F1.12...
  • Page 44 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Motor rated F2.03 0~36000rpm 1rpm ● rotation speed Motor rated F2.04 0~480V ● voltage Motor rated F2.05 0.8~2000A 0.1A ● current Motor stator Different F2.06 0.001~65.53Ω 0.001Ω...
  • Page 45 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Proportional F3.03 gain 2 of speed 0~100 ○ loop Integral time 2 F3.04 0.01~10.00s 0.01s 1.00s ○ of speed loop High frequency F3.05 F3.02~F0.10 10.00Hz ○ point of switch...
  • Page 46 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F4 Group: V/F Control Parameters 0: Linear curve 1: User-defined curve 2: 1.3 square torque-step-down V/F curve curve F4.00 ● selection 3: 1.7 square torque-step-down curve 4: 2 square torque-step-down curve 0.0 %(auto)
  • Page 47 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Low-frequency threshold of F4.12 0~10 ○ restraining oscillation High-frequency threshold of F4.13 0~10 ○ restraining oscillation F4.14 Reserved Boundary frequency of F4.15 0.00Hz~F0.10 (Maxi. frequency) 0.01Hz 30.00Hz ○...
  • Page 48 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type 13: Frequency setting source switch between X and Y 14: Frequency setting source M3 terminal switch between X and (X+ Y) F5.02 ● function 15: Frequency setting source...
  • Page 49 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F5.06 Reserved F5.09 On/off filter F5.10 1~10 ○ times 0:2-wire control mode 1 2:2-wire control mode 2 FWD/ REV F5.11 ● control mode 3:3- wire control mode 1...
  • Page 50 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type ACI upper limit F5.21 corresponding -100.0%~100.0% 0.1% 100.0% ○ to setting value ACI input filter F5.22 0.00s~10.00s 0.1s 0.10s ○ time F5.23 Reserved F5.32 F6 Group: Output Terminals Parameters...
  • Page 51 Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type 0:Running frequency 1:Setting frequency 2:Running rotation speed 3:Output current FM output 4:Output voltage F6.04 ○ selection 5:Reserved 6:Reserved 7:Reserved 8: Analog AVI input value 9: Analog ACI input value FM output lower F6.05 0.0~100.0%...
  • Page 52 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type AM output F6.12 0.0~100.0% 0.1% 100.0% ○ upper limit AM upper limit F6.13 corresponding 0.00V~10.00V 0.01V 10.00V ○ to output 0:Running frequency 1:Setting frequency 2:DC bus voltage...
  • Page 53 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F7 Group: Display Interface Parameters F7.00 User password 0~9999 ○ F7.01 Reserved F7.02 Reserved 0:Switch display status REV/JOG 1:Clear UP/DOWN setting F7.03 key function 2:Reverse running ●...
  • Page 54 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type 1~0xFFFF BIT0:AVI value BIT1: ACI value BIT2:Reserved Running F7.07 status display BIT3: Motor overload ratio ○ selection 2 BIT4: Inverter overload ratio BIT5:Running time BIT6:Counting meter value...
  • Page 55 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F8 Group: Auxiliary Function Parameters Jog running F8.00 0.00~F0.10 0.01Hz 5.00Hz ○ frequency Jog running F8.01 acceleration 0.1~3600s 0.1s ○ time Jog running F8.02 deceleration 0.1~3600s 0.1s ○...
  • Page 56 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type F8.12 FDT level 0.00~F0.10 0.01Hz 50.00Hz ○ F8.13 FDT lag 0.0~100.0% 0.1% 5.0% ○ Detecting range F8.14 of reached 0.0~100.0% (Maxi. frequency) 0.1% 0.0% ○ frequency Braking 115.0~140.0% (standard DC bus...
  • Page 57 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Inverter rated Defined F8.25 0.4~700.0kW 0.1kW ◎ power inverter Inverter rated F8.26 0.0~2000A 0.1A ◎ model current Linear speed 0 .1 ~ 9 9 9 . 9 % ( l i n e a r s p e e d = F8.27...
  • Page 58 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Sampling cycle F9.07 0.01~100.0s 0.01s 0.10s ○ Bias limit of PID F9.08 0.0~100.0% 0.1% 0.0% ○ control Feedback lost F9.09 0.0~100.0% 0.1% 0.0% ○ detecting value Feedback lost F9.10...
  • Page 59 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Motor over load 2 0 . 0 % ~12 0 . 0 % (m o t o r r a t e d FA.01 0.1% 100.0% ○...
  • Page 60 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type 0: No fault 1: Inver ter module protection (E001) 2. Over-current when accelerate (E002) Former twice 3: Over-current when decelerate FA.14 ◎ faults type (E003) 4: O v e r- c u r r e n t a t c o n s t a n t...
  • Page 61 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Output current FA.18 when fault ◎ occurs DC bus voltage FA.19 when fault 0.0V ◎ occurs Input terminal FA.20 status when ◎ fault occurs Output terminal FA.21 status when ◎...
  • Page 62 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Clear up 0:Invalid FB.07 counting meter ○ 1:Valid value Counter value FB.08 FB.09~9999 ○ setting Designated FB.09 0~FB.08 ○ counter value 0 : A c t u a l c o u n t i n g l e n g t h =...
  • Page 63 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Communication FC.04 timeout fault 0.0 (invalid), 0.1~100.0s 0.1s 0.0s ○ time 0:Alarm and coast to stop 1:No alarm and continue to run Dispose of 2:No alarm but stop according to FC.05...
  • Page 64 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Multi- step FD.06 -100~100% 0.1% 0.0% ○ speed 2 step running FD.07 0.0~6553s(m) 0.1s(m) 0.0s ○ time Multi- step FD.08 -100~100% 0.1% 0.0% ○ speed 3 step running FD.09...
  • Page 65 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Multi- step FD.20 -100~100% 0.1% 0.0% ○ speed 9 step running FD.21 0.0~6553s(m) 0.1s(m) 0.0s ○ time Multi- step FD.22 -100~100% 0.1% 0.0% ○ speed 10 step FD.23...
  • Page 66 8000B Series Modifi- Function Minimum Factory Function Descriptions cation Code Unit Setting Type Acceleration FD.34 time of 0 0~0xFFFF ○ steps Acceleration FD.35 time of 8 0~0xFFFF ○ steps 0: Restart from 1 step PLC restart FD.36 1 : R e s t a r t f r o m b r e a k - o f f ○...
  • Page 67: Chapter 6 Trouble Shooting

    8000B Series Chapter 6 Trouble Shooting 6.1 Fault and Trouble Shooting Fault Fault Type Reason Solution Code 1: Acceleration time is 1:Increase acceleration time too short 2: Ask for support 2: IGBT module 3: Inspect external equipment damaged and eliminate interference...
  • Page 68 8000B Series Fault Fault Type Reason Solution Code 1: Input voltage 1: Install input AC reactor Over-voltage at abnormal 2: Add suitable braking units E007 constant running 2: Load inertia is too speed large 1: Input voltage 1: Inspect the input power...
  • Page 69 8000B Series Fault Fault Type Reason Solution Code 1:Instantaneous over 1: Refer to over current current of inverter solutions 2:Output short circuit 2: Use the good wire 3: Cooling fans of 3: Replace cooling fan and inverter stop or clear the ventilation channel damaged.
  • Page 70 8000B Series Fault Fault Type Reason Solution Code E021 Reserved 1: Read/ Write fault of Push STOP/RESET to reset E022 EEPROM fault control parameters and ask for support 2: EEPROM damaged 1: Accelerate too fast 1:Increase acceleration time 2: Restart the motor...
  • Page 71: Common Faults And Solutions

    8000B Series 6.2 Common Faults and Solutions Inverter may have following faults or malfunctions during operation, please refer to the following solutions. No display after power on: · Inspect whether the voltage of power supply is the same as the inverter rated voltage or not with multi-meter.
  • Page 72: Chapter 7 Data Address Table Of Function Code

    8000B Series Chapter 7 Data Address Table of Function Code F0.00 F1.07 F3.05 F0.01 F1.08 F3.06 F0.02 F1.09 F3.07 F0.03 F1.10 F3.08 F0.04 F1.11 F3.09 F0.05 F1.12 F3.10 F0.06 F1.13 F3.11 F0.07 F1.14 F3.12 F0.08 F1.15 F4.00 F0.09 F1.16 F4.01 F0.10...
  • Page 73 8000B Series F5.07 F6.10 F8.13 F5.08 F6.11 F8.14 F5.09 F6.12 F8.15 F5.10 F6.13 F8.16 F5.11 F6.14 F8.17 F5.12 F6.15 F8.18 F5.13 F6.16 F8.19 F5.14 F6.17 F8.20 F5.15 F6.18 F8.21 F5.16 F7.00 F8.22 F5.17 F7.01 F8.23 F5.18 F7.02 F8.24 F5.19 F7.03 F8.25...
  • Page 74 8000B Series FA.00 FC.03 FD.32 FA.01 FC.04 FD.33 FA.02 FC.05 FD.34 FA.03 FC.06 FD.35 FA.04 FD.00 FD.36 FA.05 FD.01 FD.37 FA.06 FD.02 FA.07 FD.03 FA.08 FD.04 FA.09 FD.05 FA.10 FD.06 FA.11 FD.07 FA.12 FD.08 FA.13 FD.09 FA.14 FD.10 FA.15 FD.11 FA.16...
  • Page 75 Guangzhou Sanjing Electric CO., LTD. TEL: (00)86-20-6660 8588 6660 8519 FAX: (00)86-20-6660 8589 ADD: SAJ Innovation Park, No.9, Lizhishan Road, Science City, V1.0 Guangzhou High-tech Zone, Guangdong, P.R.China Inverter...

Table of Contents

Save PDF