7.4 Cables

7.4.1 To do a check of the power switch and power
cord
WARNING: Disconnect the power cord from the
power outlet.
Do a check of the power cord, the cable gland and
the strain relief for damage.
Do a check of the power plug and the power switch.
If the power plug is burned, replace it.
Do a check of the electrical function with a
multimeter.
7.4.2 To do a check of the PRCD
The product has a PRCD installed on the power cord.
The PRCD is for protection and engages if an electrical
fault occurs.
1. Connect the power plug to the power outlet.
2. Push the "RESET" button. The red indicator shows
that the current is connected.
3. Pull the power plug out of the power outlet. The red
indicator goes off.
4. Do step 1 and 2 again.
1332 - 001 - 04.03.2021
5. Push the "TEST" button. The red indicator goes off.
6. Push the "RESET" button again. The red indicator
shows that the current is connected.
7.4.3 To examine the electrical cables of the PRCD
The PRCD only lets through current when it is
connected to the power outlet. Examine the connection
points with a multimeter.
1. Remove the 4 screws and pull apart the ends of the
PRCD.
2. Turn the PRCD to the other side.
Function test - 33