8 ERROR CODES

8
ERROR CODES
Error management codes are used to indicate that an error has occurred in the welding
process. It is indicated in the display via a pop-up menu.
This manual describes the error codes for the EAC 10. The error codes for other units are
described in the manuals for these units.
Error code
LAF, TAF
Aristo®
1000
6
4201, 4202,
4203
7
8
11
8411
sub-code 0
12
12, 93
14
14, 95
0463 613 101
Description
High temperature
The power source has overheated and cancels welding. Welding
is permitted again when the temperature falls below the
maximum temperature parameter.
Action: Check that the cooling air inlets or outlets are not
blocked or clogged with dirt. Check the duty cycle being used to
make sure that the equipment is not overloaded. If the error
persists, send for a service technician.
Low welding current
The weld arc has been shut down due to too low welding current
during the welding process.
Action: Is reset at next weld start. If the error persists, send for a
service technician.
Low battery voltage
Battery voltage too low. If the battery is not replaced, all stored
data will be lost. This error does not disable any functions.
Action: Contact a service technician to replace the battery.
Speed error on a motor, (wire feed, travel motor)
A motor cannot maintain its speed. Welding stops.
Action: Check that the wire feed has not jammed or runs too
fast. If the error persists, send for a service technician.
Internal communication error (warning)
The load on the system's CAN-bus is temporarily too high. The
power source may have lost contact with the control unit.
Action: Check that all the equipment is correctly connected. If
the error persists, send for a service technician.
Communication error
The system's CAN bus has temporarily stopped working due to
the load being too high. The current welding process stops.
Action: Check that all the equipment is correctly connected. Turn
off the power supply to reset the unit. If the error persists, send
for a service technician.
- 40 -
© ESAB AB 2020

Advertisement

Table of Contents
loading

This manual is also suitable for:

0904 200 880

Table of Contents