8 ERROR CODES
Error code
LAF, TAF
Aristo®
1000
17
8117
32
43
71
44
100
168, 169
8411
sub-code 1
2310
4
3205
88
58.3 / 5010 High inductance
0463 613 101
Description
Lost contact with the unit
Action: Check wiring and the connector between the control unit
and power source. If the error persists, send for a service
technician.
No gas flow
Start prevented.
Action: Check the gas valve, hoses, and connectors.
High welding current
Power source has switched off the welding process because the
current has exceeded the maximum current parameter for the
power source.
Action: Is reset at next weld start. If the error persists, send for a
service technician.
Start pause welding current
The welding process has stopped because it has not advanced
within 10 seconds.
Action: Is reset at next weld start. If the error persists, send for a
service technician.
A motor has stopped.
There are no pulses from the motor pulse transducer.
For LAF and TAF: 168 = Motor M1 (Wire feeder motor),
169 = Motor M2 (Travel motor)
Action: Check the motor cables. Replace the pulse transducer.
Current servo saturation
The power source has temporarily delivered maximum current.
Action: If the error persists, try lowering the weld data.
High DC voltage
Action: Check if the main voltage is too low or too high.
Inductance is too high, depending on long welding cables and/or
high weld data.
Action: Try adjusting the weld data.