Installation introduction

Installation precaution
- Do not install the water heater in the position where exposed to gas, vapours or dust.
- Install the tank unit and external unit on a flat, solid surface.The surface can support the
machine weight and the condensate water can be drained freely.
- Noise due to operating and air flow do not bother neighbors.
- Make sure there is sufficient space left for installation and maintenance.
- There is no strong electromagnetic interference around that may affect control
functions.
- There is no sulfur gas or mineral oil existing at the installation place, which may cause
corrosion of the machine and the fittings.
- The water pipe for the water heater used at temperatures below 0°C shall not freeze.
- It shall not be set in rooms where a heating system is used so that heating supply to the
room will not be affected.
- It shall not be set inside a totally-enclosed space.
- The air taken in must in no event be dusty.
- Install the internal unit in a dry, frost-free room.
- Temperature of the ambient air or of the air taken in by the heat pump for optimum
running: from 10 to 35°C.
- Discharge of condensate:The condensate or water, which is formed in the outdoor unit
during heating operation, must be eliminated, freely or through the drain. Fix the drain
connection into the hole which is located on the bottom of the unit and connect the
plastic tube with the connector. Ensure that the condensate water runs out in a suitable
drain and make sure the discharge is made without hindrance.
Elbow
Drain pipe
Keep an adequate distance between the working heat pump and the resting places.