Installation

Installation precautions
During installation of the water heater, some clearances (at lease 250mm
vertically, at least 700mm horizontally) shall be left to facilitate in future
maintenance. If the water heater is inserted in the pinch plate, the downside
of the pinch plate is movable, ensuring that the maintenance cover can be
removed during maintenance.
Make sure that the tap water inlet pressure is not less than 0.05MPa, and the
maximum pressure not exceeding 0.75MPa.
The water heater shall be installed indoors, with the ambient temperature
above 0
C, and the piping shall be centralized.The hot water outlet shall be
o
close to the hot water tap as far as possible. It the distance between them is
more than 8m, the hot water piping shall be heat insulated, to reduce heat
loss.
The water heater shall be installed on the solid and firm wall, which can bear
two times of the water-filled water heater weight.No adhesive is allowed to
avoid accidental falling of the water heater. If the bearing wall or hollow brick
wall is not used, proper protections must be taken, e.g. addition of supports,
use of wall-through screws, mounting of backing plates.
The water heater shall be installed at the place which is easy of access and
provided with floor drain. Make sure that leakage of the water tank or pipe will
cause no damage to surrounding or underground facilities. It is preferably
installed above the pedestal pan, bath, washbasin or doorframe to protect
users against depressing or insecure feelings.
Correct the water inlet and outlet pipes properly. The safety valve shall be
installed as required, without any unauthorized modification. The pressure
relief of safety valve shall be connected to the atmosphere, without any
clogging.
Use the test pencil to check if the live wire and zero line are properly
connected. Do not power it on for heating until you make sure that the water
heater is water-filled, all connections are free of leak and the power is
satisfactory.
To avoid hazards due to accidental reset of the thermal breaker, the water
heater can be neither powered by the timer or other external switch gears,
nor connected to the circuit switched frequently via other devices.
To avoid accidents, our accessories must be installed, and cannot be
replaced or substituted at discretion. In case of damaged accessory, contact
our maintenance department for repair, and replace with new ones provided
by us, otherwise we have no responsibility for any direct or indirect loss