  • Page 1 Heat pump Water Heater Operation and Installation Manual ELECTRICITE Model HP150M5 Please read this manual carefully prior to your use of this water heater. The appearance of the water heater given in this manual is for reference only.
  • Page 2: Table Of Contents

    9.Faults and protection ......................28 10.Product Fiche ........................29 Dear users of Haier, Thank you for choosing Haier products. Please read this manual carefully and follow the operation and safety instruction to ensure best installation and utilization of the product.
  • Page 3: Safety Instructions

    Safety instructions (to be followed at any time) Interpretation of marks and symbols Failure to respect these instructions may lead to serious malfunctions of the device and to risks for the user Instructions with this warning mark shall be strictly followed during operation. They relate to product and body safety of users.
  • Page 4 Safety instructions (to be followed at any time) The outlet water temperature Means for disconnection from of a water heater is typically the main supply having a higher than the temperature contact separation in all poles indicated on the display. Hot that provide full...
  • Page 5 Safety instructions (to be followed at any time) Rotate the safety valve handle Water heaters shall once a month. The valve equipped with a dedicated works well if there is water power line residual flowing out, otherwise check current circuit breakers. The for blocking and replace the action current...
  • Page 6: Instructions On Transportation And Storage

    Instructions on transportation and storage 1. During transportation or storage, the heat pump water heater shall be packed in the undamaged package to avoid damage to appearance and performance of the product; 2. During transportation or storage, the heat pump water heater shall be in the upright position;...
  • Page 7: Technical Parameters

    Net/Gross weight 67/89kg * The COP and noise level data was tested in Haier lab. The COP values obtained with external air temperature of 7°C and 14°C, inlet water temperature of 10°C and set temperature of 54°C (according to EN 16147).
  • Page 8: Description Of Parts And Components

    Description of parts and components Heat pump structure Condensate outlet  HP HC START STOP MODE TIMER BOOST Inlet for cold Hot water water/drain outlet outlet Air outlet Air inlet Accessories Support Part Heat pump Instruction Drainage pipe for Safety name water heater manual...
  • Page 9 Description of parts and components Exploded view Description Description Evaporator Electric cover Top cover Electric heater Air grille Display panel Air channel - front Cover for display Control box Motor Front cover Air channel - back Compressor Back cover Four-way valve Support plate Electronic expansion valve...
  • Page 10: Installation Introduction

    Installation introduction Installation precaution - Do not install the water heater in the position where exposed to gas, vapours or dust. - Install the appliance on a flat, solid surface.The surface can support the machine weight and the condensate water can be drained freely. - Noise due to operating and air flow do not bother neighbors.
  • Page 11 Installation introduction Installation dimensions Unit:mm Model 1680 HP150M5...
  • Page 12 Installation introduction Installation dimensions Note: These two expansion bolts can support 250kg weight at least . Please use the expansion bolts adapted to your wall material. Installation angle refer to the following After the installation is completed, it is necessary diagrams:...
  • Page 13 Installation introduction Air connection - Remove air grille first. click - Install diameter 160mm duct. - Pressure drops from duct must be lower than or equal to the static pressure of the fan. - If the pressure drops out of range, the performance of the appliance will be impaired.
  • Page 14 Installation introduction Advised positions Garage or laundry room (without ducts): -Unheated room. -Enables recovery of the free energy released by your vehicle’s engine when switched off after use or by household appliances in operation. Laundry room (with one duct): -Unheated room. -Enables recovery of the free energy released by your vehicle’s engine when switched off...
  • Page 15 Installation introduction Installation caution When making the connections, you should respect the standards and local directives. - Before making the connection, rinse the water inlet pipes, in order not to introduce metal or other particles into the tank. - Select copper pipes for pipeline connection. - The inlet water pressure is between 0.1~0.5MPa.
  • Page 16 Installation introduction Pipeline installation diagram Installation A Thermostatic valve Check valve 230V 50Hz Hot water Water outlet of outlet safety valve Outlet of condensate water Pressure Stop Check valve valve relief valve Drain valve Cold water inlet Water outlet Installation B(for France only) Connected to water inlet of the water tank Thermostatic...
  • Page 17 Installation introduction Electrical connections precautions WARNING - Only qualified professionals may carry out electrical connections, always with the power off. - The earthing shall comply with local standards. - Water heaters shall be equipped with a dedicated power line and residual current circuit breakers.
  • Page 18 Installation introduction Off-peak power signal wire connection 123kwh Auto Off-peak power signal wire (2*0.75mm ,Black wire) Power cable (3*1.5mm...
  • Page 19 Installation introduction Wiring diagram Compressor CN11 capacitor Four-way valve Discharge temperature CN19 sensor CN16 MAIN BOARD Defrost temperature White sensor Ambient temperature White sensor White Current transformer Suction temperature sensor ︳ Blue Water tank temperature Black sensor Compressor CN27 CN24 ︳...
  • Page 20: Operation And Functions

    Operation and functions Display Functions & Protections Electrical leakage protection The control system of this machine features an electricity leakage protection function. 3-minutes protection When starting the machine after electricity input, the system will start after approximately 3 minutes ,which is considered to be normal. When restarting the machine immediately after shutdown, the system goes into the protection mode and starts after approximately 3 minutes, which is considered to be normal.
  • Page 21 Description of the pictograms Symbol Description Power ON/OFF switch Working mode selection Confirm button Timer adjust Boost mode. Heat pump and auxiliary power are activated at the same time. Auto mode -Optimised management of the heat pump and the electrics for guaranteed comfort;...
  • Page 22 Description of the pictograms Symbol Description Boost mode. Heat pump and Auxiliary electrical heater are activated at the same time(only in AUTO mode). Heat pump working icon. Auxiliary electrical heater working icon. When the PV function is turned on, the setting temperature will be automatically adjusted to 65°C,when the PV effective signal is received, the heat pump and electric heating will be turned on at the same time.
  • Page 23 Operating functions Installer settings - To open the installer settings, press switch off the system, then press at the same time for 10 seconds. - When menu is open, press to change the value of the settings. - Press to confirm the settings. - Press to close the menu.
  • Page 24: Checking And Maintenance

    Checking and maintenance - Installation and maintenance of the appliance must be done by a qualified professional . - Before working on the appliance,Shut down the machine and cut off the power supply . - Do not touch with wet hands. - Maintenance operations are important to guarantee optimum performance and extend the life of the equipment.
  • Page 25: Faults And Protection

    Faults and protection Digital Release Fault type Action indication Operating temperature protection Air exhaust temperature protection Compressor protection After fault is solved, Evaporation high temperature switch on power protection supply for release Compressor over-current Over-current protection protection Electricity leakage alarming The system will automatically cut off power supply if any line fault occurs Over temperature alarming The actual water temperature≥85℃...
  • Page 26: Product Fiche

    Mixed water at 40 °C 195.9 Load profiles of water heaters, Type Qingdao Economic & Technology Development Zone Haier Water-Heater Co.,Ltd. Manufacturer Haier Industry Park, Economic & Technology Development Zone, 266101 Qingdao, Address PEOPLE'S REPUBLIC OF CHINA Heat pump water heater Denomination Hot water...