Video Intercom Face Recognition Door Station with 4.3-inch Screen User Manual
Note
The dimension of the gang box is 364 mm (W) × 118 mm (H) × 40 mm (D).
The installation hole should be bigger than the actual size. The suggested
dimension of the installation hole is 364.3 mm (W) × 118.6 mm (H) × 40.2 mm
(D).

3.2 Flush Mounting with Gang Box

Steps
1. Cave an installation hole in the wall. Pull the cable out from the wall.
Note
The suggested dimension of the installation hole is 364.3 mm (W) × 118.6
mm (H) × 40.2 mm (D).
The suggested length of the cables left outside is 250 mm.
2. Install the gang box into the wall.
1) Remove the plastic sheet of the gang box with the tool.
2) Insert the gang box into the installation hole. Mark the gang box screw holes'
position with a marker, and take out the gang box.
3) Drill 4 holes according to the marks on the wall, and insert the expansion
sleeves into the screw holes.
4) Fix the gang box with 4 expansion bolts.
3. Fix the gap between the gang box and wall with concrete. Remove the mounting
ears with tool after concrete is dry. Connect the cables according to the Wiring
Description.
4. Insert the door station into the gang box. Slide the door station down and fix it
with 2 set screws. Apply Silicone sealant among the joints between the device
and the wall (except the lower side) to keep the raindrop from entering.
9