Video Intercom Face Recognition Door Station with 4.3-inch Screen User Manual
Name
DOOR
Power Supply
Note
•
Alarm input interface cannot be edited. Refers to the actual model.
•
You can only wire the SEN1/SEN2 terminal with the door contact. And wire the
BTN1/BTN2 terminal with the exit button.
2.2 Wiring Description
2.2.1 Door Lock Wiring
Terminal
NC1
COM1
NO1
GND
NC2
COM2
NO2
GND
DC 12 V
Description
Door Lock Relay Output 1(Normally
Close)
Common Interface 1
Door Lock Relay Output 1(Normally
Open)
Grounding
Door Lock Relay Output 2(Normally
Close)
Common Interface 2
Door Lock Relay Output 2(Normally
Open)
Grounding
12 VDC Power Input
5