Receiver reset

S1012_GR-12L_DE_V1sh
If the red LED of the GR-12L HoTT lights up again constantly, the
"Binding" has failed. Change the positions of the associated
antennas and try the entire procedure again.
To reset the receiver, press and hold its SET button while turning on
the power to the receiver:
If the reset was triggered with the transmitter switched off or with
an unbound receiver, the red LED of the receiver GR-12L HoTT starts
to flash after about 3 seconds. The button will now be released.
If the reset is performed with a not bound receiver, you can then
start a binding process at any time.
If a reset has already been performed on an already-bound receiver
and the associated model memory is active in the switched-on trans-
mitter, then the red LED of the receiver GR-12L HoTT should go out
and thus signal a correct connection to the transmitter. Otherwise
the process has to be repeated.
Notes
• Through a RESET ALL of the settings in the receiver are brought
to the factory settings with the exception of the HoTT synchro-
nization information!
• If a reset is performed accidentally, all of these settings that
were made using the "Telemetry" menu in the receiver should
be restored.
• Resetting is particularly recommendable when you want to
switch a receiver to a different model. This makes it easy to keep
settings which do not match from being transferred.