Set the marking options for pulse marking

In the menu "Mark options" parameters for a pulse marking are set.
Generally the marking power should be selected as small as possible so that
the template does not overheat. Increase the marking time with unsatisfactory
marking results first, before the marking power is increased. However with very
long marking time the stencil also heats up.
During a pulse marking the current is briefly switched off during a marking, so
that the stencil does not overheat. In addition it is possible to shift between
alternating (AC) and direct current (DC) during the pulse marking. This is used
particularly with deep markings.
The following parameters can be changed in the menu "Mark options":
Pulse marking must be ON so that the two parameters "On periode" and "Off
Pulse marking
periode" are considered during a marking.
1. Press ↓ (5) in menu "Mark options" until parameter "Pulse marking"
2. Press ENTER (6).
3. Press ↓ (5) until pulse marking is ON or OFF.
4. To reject the settings: press MENU (7). To assume the settings: press
Setting the
During a pulse marking the entire marking time divides itself into sections of on
on periode
periodes and off periodes. During the on periode voltage is impresses and
current flows.
5. Press ↓ (5) until parameter "On periode" appears.
6. Press ENTER (6).
7. To increase the on periode: press ↑ (4).
8. To decrease the on periode: press ↓ (5).
9. To reject the settings: press MENU (7). To assume the settings: press
ÖSTLING Markiersysteme GmbH
Pulse marking.
On periode.
Off periode.
DC/AC automatic.
DC/AC time.
DC/AC marking power.
appears.
ENTER (6).
Menu "Mark options" appears.
Each press increases the time of the on periode in steps of 0.1 s. The maxi-
mum value is 5.0 s.
Each press decreases the time of the on periode in steps of 0.1 s. The mini-
mal value is 0.1 s.
ENTER (6).
Menu "Mark options" appears.