Setting the
The marking power changes with the impressed voltage. In order to achieve a
marking power
long service life of the stencils, the marking power should be selected as small
as possible. Increase the marking time with unsatisfactory marking results first,
before the marking power is increased.
1. Press ↓ (5) in menu "Adjustment" until parameter "Mark power" appears.
2. Press ENTER (6).
3. To choose alternating or direct current: press =/~ (8).
4. To increase the marking power: press ↑ (4).
5. To decrease the marking power: press ↓ (5).
6. To reject the settings: press MENU (7). To assume the settings: press
Setting the
During the marking time voltage is impresses and current flows. With very long
marking time the electrolyte heats itself, the stencil becomes hot. The service
marking time
life of the stencil is reduced.
7. Press ↓ (5) until parameter "Mark time" appears.
8. Press ENTER (6).
9. To increase the marking time MT: press ↑ (4).
10. To decrease the marking time MT: press ↓ (5).
11. To reject the settings: press MENU (7). To assume the settings: press
ÖSTLING Markiersysteme GmbH
Arrows points at "MP = ...".
-
AC (alternating current) for black/white marking.
-
DC (direct current) for deep marking.
LED (3) above the pushbutton shows the selected current type.
Each press increases the marking power in steps of 0.2 units. The maxi-
mum value is 24.0.
Each press decreases the marking power in steps of 0.2 units. The mini-
mum value is 0.2.
ENTER (6).
Menu "Adjustment" appears.
Arrow points at "MT = ...".
Each press increases the marking time in steps of 0.1 s. The maximum
value is 15.0 s.
Each press decreases the marking time in steps of 0.1 s. The minimum
value is 0.1 s.
ENTER (6).
Menu "Adjustment" appears.
B_EU_EMP_en.doc
Operation manual EMP
26
Need help?
Do you have a question about the EMP/MODULMAT and is the answer not in the manual?