OSTLING EMP/MODULMAT Operating Manual page 27

Electrolytic marking system
Table of Contents

Advertisement

Setting the
During the pumping time the electrolyte pump runs. The pumping time begins at
pumping time
the same time as the marking time.
12. Press ↓ (5) until parameter "Pump time" appears.
13. Press ENTER (6).
14. To increase the pumping time PT: press ↑ (4).
15. To decrease the pumping time PT: press ↓ (5).
16. To reject the settings: press MENU (7). To assume the settings: press
Setting the
During the retarding time no voltage is impressed, the marking is "retarded".
retarding time
The retarding time begins when the foot switch is pressed.
17. Press ↓ (5) until parameter "Retarder" appears.
18. Press ENTER (6).
19. To increase the retarding time RT: press ↑ (4).
20. To decrease the retarding time: press ↓ (5).
21. To reject the settings: press MENU (7). To assume the settings: press
Enter the
Entering an electrolyte designation makes sense when all adjustments are
electrolyte
saved in a file (see page 31).
22. Press ↓ (5) until parameter "Electrolyte" appears.
23. Press ENTER (6).
24. Leaf through number 0 - 9 and letters A - Z and a - z with ↑ (4) und ↓ (5).
25. Repeat step 24 until the electrolyte designation is entered (max. 5 digits).
ÖSTLING Markiersysteme GmbH
Arrow points at "PT = ...".
Each press increases the pumping time in steps of 0.1 s. The maximum
value is 10.0 s.
Each press decreases the pumping time in steps of 0.1 s. The minimum
value is 0.1 s.
ENTER (6).
Menu "Adjustment" appears.
Arrow points at "RT = ...".
Each press increases the retarding time in steps of 0.1 s. The maximum
value is 10.0 s.
Each press decreases the retarding time in steps of 0.1 s. The minimum
value is 0.1 s.
ENTER (6).
Menu "Adjustment" appears.
Arrow points at the electrolyte designation or at an empty row under
"Electrolyte".
Press ENTER (6) to select a number or letter.
The cursor jumps one digit to the right.