Chapter 2
Installation and Configuration
On the Device Manager page, look at the items listed under the
National Instruments GPIB Interfaces icon. If there is no
National Instruments GPIB Interfaces icon or if a circled X or
exclamation point (!) appears through the eagle icon, the PC/104-GPIB
is not working properly. Figure 2-15 shows an example of a
PC/104-GPIB that is working properly, and Figure 2-16 shows an
example of a PC/104-GPIB that is not working properly.

Figure 2-15. PC/104-GPIB That Is Working Properly

Figure 2-16. PC/104-GPIB That Is Not Working Properly

You can see if the problem is a resource conflict by looking at what
resources are conflicting, if the PC/104-GPIB appears under the
National Instruments GPIB Interfaces icon. Double-click on the
PC/104-GPIB name and click on the Resources tab, which provides
information about the hardware resources assigned to the
PC/104-GPIB. The Conflicting Device List lists any conflicts. If
conflicts exist, use the Setting based on drop-down list and the
Change Setting button to select conflict-free resources for the
PC/104-GPIB.
If you cannot find conflict-free resources for the PC/104-GPIB, or if
no conflicts are listed, refer to the
Troubleshooting Device Manager
Problems
section of Appendix B,
Troubleshooting and Common
Questions, to resolve the problem.
© National Instruments Corporation
2-19