Miele ProLine Operating And Installation Instructions page 54

Table of Contents

Advertisement

Installation
This hob is a class 3 appliance and is
suitable for use with natural gas or li-
quid gas.
Category in acc. with EN 30
United Kingdom, Ireland
II2H3+
20, 28–30/37 mbar
Depending on country of destination
this appliance is set up for connection
to natural or liquid gas. See adhesive la-
bel on the appliance.
Depending on country of destination,
jets are supplied for conversion to a dif-
ferent type of gas. If the appropriate jets
have not been supplied with the appli-
ance, you will need to contact Miele.
Conversion to another type of gas is
described in the section "Converting to
another type of gas".
Connecting the hob
The hob is supplied with a conical ¹/₂"
gas connection point. There are two
connection options:
- Fixed connection
- Flexible connection in accordance
with DIN 3383 Part 1, maximum
length 2000  mm. (Not for the UK.)
Risk of explosion due to gas
leakage.
Unsuitable sealant will not ensure the
required leak protection for connec-
tions.
Ensure that a suitable sealant is
used.
54
Using a 90° angle
a Connection R ¹/₂" with test point -
ISO 7-1 (DIN EN 10226)
b 90° elbow
The installation height in the area of
the gas connection is increased by
approx. 60 mm.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs 1011-1Cs 1021-1

Table of Contents