Management Features - 3Com 4007 Getting Started Manual

3com 4007: quick start
Hide thumbs Also See for 4007:
Table of Contents

Advertisement

Slots for two Enterprise Management Engine
(EME) management modules that do not take up
interface module or switch fabric module space.
Switch 4007 starter kits are supplied with with one
management module (Model Number: 3CB9EME)
installed in the lower slot. You can install a second
management module to provide standby
management support.
The management module uses the management
bus to send commands to all installed interface
modules and the switch fabric module and to
collect information from the modules.
A single passive backplane that enables the use of
multiple networking technologies, defined by the
type of switch fabric module that is installed.
One slot for a switch fabric module in the chassis
to provide optimal network performance.
Gigabit Ethernet starter kits (Model Numbers
3C16810 and 3C16811) have one 24-port
Switching Fabric (Model Number: 3CB9FG24T)
preinstalled in slot 7.
Fast Ethernet starter kits (Model Numbers
3C16815 and 3C16816) have one 9-port
Switching Fabric (Model Number: 3CB9FG9)
preinstalled in slot 7.
Slots for two power supplies to supply 930 watts
with n + 1 redundancy and 1860 watts without
n + 1 redundancy, depending on the type and
quantity of installed modules.
Switch 4007 starter kits have one 930W AC Power
Supply (Model Number: 3CB9EP9) preinstalled in
the lower bay.
Power supplies that you can add or replace while
the chassis is running (referred to as warm
swapping).
Slots for six interface modules. In Switch 4007
starter kits, modules are preinstalled in slots 1 and
2, and the remaining slots are empty.
Packet switching at an aggregated bandwidth of
up to 30 Gbps.
Power fault-tolerant mode where you can reserve
the power of a single power supply (930 watts) to
act as a backup if the other power supply fails.
One exhaust fan tray (with the power and
reliability of four fans) to make sure that the
chassis maintains the optimal temperature for
operation.

Management Features

You can manage the Switch 4007 through:
An out-of-band terminal interface
Simple Network Management Protocol (SNMP)
3Com Transcend Network Supervisor
3Com Transcend Network Control Services
A standard Telnet client-to-server application
Embedded Web-based management
To learn more about management features, see
Chapter 5, "Management Tools".
Overview
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

3cgbic97 - switch 4007 70km gigabit enet gbic

Table of Contents