Error
1. Saw blade comes loose after switch-
ing off the motor
2. Motor does not start
3. Wrong direction of motor rotation
motor
4. Motor does not perform, fuse does
not activate
5. Fire stains at cutting surface

Troubleshooting

Possible reason
Fastening nut is too loose.
Failure of mains fuse
b) Extension cable is defective
c) Connections at motor or switch
are not ok
d) Motor or switch are defective
a) Condenser defective
b) Incorrect connection
a) Cross-sectional area of extension
cable is not sufficient
b) Overloading due to blunt saw
blade
a) Blunt saw blade
b) Wrong saw blade
Remedy
Tighten the fastening nut (right-handed
thread)
a) Check mains fuse
b) Replace extension cable
c) must be checked by electrician
d) must be checked by electrician
a) must be checked by electrician
b) Reverse of polarity of the mains socket
by electrician
a) see electrical connection
b) Replace saw blade
a) Sharpen, replace saw blade
b) Replace saw blade