168
C
3: I
HAPTER
NTERFACE
display controller e1
M
C
ANAGEMENT
OMMANDS
View
System view
Parameter
number: The CE1/PRI interface number.
Description
Using the controller e1 command, you can enter a CE1/PRI interface view.
Example
Enter the view of the interface E1 3/0/0.
[3com]controller E1 3/0/0
[3com-E1 3/0/0]
Syntax
display controller [ e1 number ]
View
Any view
Parameter
number: Interface number.
Description
Using the display controller e1 command, you can display the information related
to a CE1/PRI interface.
Executing this command will display the following information:
Physical state of interface
Clock mode of interface
Frame check mode of interface
Line code format of interface
Example
Display the information related to the E1 interface.
[3com]display controller E1 3/0/0
E1 1-0 is down.
Applique type is Channelized E1 - 75 OHM unbalanced
Framing is NO-CRC4, Line Code is HDB3, Source Clock is slave.
Alarm State is Loss of Frame Alignment.
Need help?