display interface
ethernet
M
C
ANAGEMENT
OMMANDS
View
Interface view
Parameter
None
Description
Using the shutdown command, you can shut down an interface. Using the undo
shutdown command, you can enable an interface.
This command takes effect not only on physical interfaces but also on tunnel and
MFR interfaces.
In some circumstances, such as when you are modifying the operating parameters
of an interface, the modification do not take effect immediately. Rather, you must
shut down the interface and re-enable it.
For a related command, see display interface.
Example
Shut down Ethernet 0/0/0.
[
3com
-Ethernet0/0/0]shutdown
% Interface Ethernet0/0/0 is down
% Interface Ethernet0/0/0 changed state to DOWN
% Line protocol ip on interface Ethernet0/0/0, changed state to DOWN
Syntax
display interface ethernet interface-number
View
Any view
Parameter
interface-number: Interface number. If no interface has been specified, the
configuration and state information of all the interfaces will be displayed.
Description
Using the display interface ethernet command, you can view the configuration
parameters, current running state, and some other information of an Ethernet
interface.