8-2-2. Format of the remote register R
Indicated value_Selection: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E0
The data varies with the remote output [Value selection 1].
MSB
3
L
10
th digit
H
Sign
Indicate the same format with the command data (numerical values).
Holding value: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E8
Store the indicated values (when in operation) during the Hold mode.
The data varies Peak or Bottom with the remote output [Value selection 2].
MSB
3
L
10
th digit
H
Sign
Indicate the digits (BCD data) and signs in the same manner as that of the above.
MEMO
Store the holding values (indicated values) in the remote register, based on the following conditions.
The updating rate is approx. 4 times/sec (= Display (Numeric Value) updating rate).
● When the "Display Mode" is "Hold display mode" in the "Measure Mode Setting", the holding value
(indicated value), immediately after turning ON the HOLD command, appears during the Detecting interval.
● The holding value (indicated value), set the decimal point position in the "Calibration" window, appears.
Measured value: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02EA
Store the scaled calibration data (the same data during the tracking) of the sensor inputs, irrespective of the Hold
mode.
MSB
3
L
10
th digit
H
Sign
Indicate the digits (BCD data) and signs in the same manner as that of the above.
MEMO
Store the measured values (tracking values) in the remote register, based on the following conditions.
The updating rate is 4000 times/sec (= sampling rate).
● Not affected by the settings of the "Display Mode" in the "Measure Mode Setting",
● Not affected by the decimal point position of the "Calibration".
Error code: 4 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 02E6
Store the WGA-910A error codes.
MSB
All "0"
Indicate the error codes as follows.
0000: None (Healthy),
0011: Calibration error,
M
2
4 bits
10
th digit
4 bits
All "0"
2
4 bits
10
th digit
4 bits
All "0"
2
4 bits
10
th digit
4 bits
All "0"
4 bits
All "0"
0001: OVER error (input),
0100: Memory error,
1
4 bits
10
th digit
4 bits
All "0"
1
4 bits
10
th digit
4 bits
All "0"
1
4 bits
10
th digit
4 bits
All "0"
4 bits
All "0"
0010: Over error (indicated value)
0101: Bridge voltage error
16
to 02E1
H
H
0
4 bits
10
th digit
4
4 bits
10
th digit
to 02E9
H
H
0
4 bits
10
th digit
4 bits
10
4
th digit
to 02EB
H
H
0
4 bits
10
th digit
4 bits
10
4
th digit
H
4 bits
Error code
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB
4 bits

Advertisement

loading