8-1-2. Format of the remote register M
Measureing Condition limited data: 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 01E0
Writes the pre-set values of the Measureing Condition (operation pattern) limited data by using the [Command
processing request 1].
Pre-set values: [HH] comparator value_H/L, [HI] comparator value_H/L. [LO] comparator value_H/L. [LL]
comparator value_H/L
MSB
3
L
10
th digit
H
Sign
Store the numerical values of each digit as the BCD data.
Example: 9 (Decimal) = 2
When a numerical value of each digit is larger than 9, the product treats the numerical value as "9."
You cannot set the decimal point position since it is based on the calibration data.
Indicate the sign as follows.
0000: Positive (+),
Example: Pre-set data of the [LO] comparator value: "-56789"
Command data (numerical values): 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 01EC
Write the pre-set values of the numerical values by using the [Command processing request 2].
MSB
L
10
3
th digit
H
Sign
Indicates the digits and signs in the same manner as that of the above Measureing Condition limited data.
Example: Pre-set data of the rated capacity: "06400"
Command data (assigned values): 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 01EC
Write the pre-set values of the assigned values by using the [Command processing request 2].
MSB
L
All "0"
H
All "0"
Indicate the digits in the same manner as that of the BCD data.
Example: Pre-set data of the number of moving averaging times: "11" (2048 times)
● Command data (Clock 1): 32 bits BCD
Buffer address (Station number: 1, Number of occupied stations: 4 stations): 01EC
Write the pre-set values of the Clock 1 (Year, Month, Day) by using the [Command processing request 2].
MSB
L
Month (10
1
th digit) 4 bits
H
All "0"
Indicate the digits in the same manner as that of the BCD data.
Example: Pre-set data of Clock 1 (Year, Month, Day): "160129"
R
2
4 bits
10
th digit
4 bits
All "0"
3
2
1
×1 +2
×0 +2
×0 + 2
0001: Negative (-)
0110 0111 1000 1001 (Upper row: 16 bits BCD of the L)
0001 0000 0000 0101 (Lower row: 16 bits BCD of the H)
4 bits
10
2
th digit
4 bits
All "0"
0110 0100 0000 0000 (Upper row: 16 bits BCD of the L)
0000 0000 0000 0000 (Lower row: 16 bits BCD of the H)
4 bits
All "0"
4 bits
All "0"
0000 0000 0001 0001 (16 bits BCD of the upper row)
Month (10
0
th digit) 4 bits
4 bits
All "0"
0000 0001 0010 1001 (Upper row: 16 bits BCD of the L)
0000 0000 0001 0110 (Lower row: 16 bits BCD of the H)
1
4 bits
10
th digit
4 bits
All "0"
0
×1 = 1001
4 bits
10
1
th digit
4 bits
All "0"
4 bits
10
1
th digit
4 bits
All "0"
Day (10
1
th digit) 4 bits Day (10
4 bits
Year (10
1
th digit) 4 bits
13
to 01E7
H
H
0
4 bits
10
th digit
4 bits
10
4
th digit
to 01ED
H
H
4 bits
10
0
th digit
4
4 bits
10
th digit
to 01ED
H
H
4 bits
10
0
th digit
4 bits
All "0"
to 01ED
H
H
0
th digit) 4 bits
Year (10
0
th digit) 4bits
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB
4 bits
4 bits
LSB

Advertisement

loading

This manual is also suitable for: