Starting Problems (continued)
Condition
___________________________________________________________________________________________
Engine cranks, but does not start
(if engine cranks, cause of prob ­
lem is not in interlock system).
________________________________________________________________________________________________________________________________________________________
Engine cranks (but should not)
with traction pedal out of neutral.
________________________________________________________________________________________________________________________________________________________
Engine cranks (but should not)
with PTO switch ON.
®
Reelmaster
335-D
Possible Cause
Injection pump ETR solenoid wir-
ing loose or corroded.
Injection pump ETR solenoid faulty.
Glow relay faulty.
Glow relay/glow plug wiring loose,
corroded or damaged.
Glow plugs faulty.
Engine or fuel system problem.
Traction switch out of adjustment
or faulty.
PTO switch faulty.
Page 5 - 9
Correction
Clean and tighten or repair as
necessary.
Test solenoid. Replace if faulty.
Test glow relay. Replace if faulty.
Check wiring and connections.
Clean, tighten or repair as neces­
sary.
Test glow plugs and replace if
faulty.
See Troubleshooting section of
Chapter 3 - Engine.
Adjust or replace traction switch.
Replace PTO switch.
Troubleshooting