2.1.3 WALL MOUNTING

First, make an outline of how the Rack PDM Chargers are to be placed.
TIP: If several Rack PDM Chargers (or Battery Pack Chargers) are to be mounted
close to each other, mount them so that there is enough space between them to be
able to disconnect the handsets (vertical distance) and to be able to open the top cover
(horizontal distance).
TIP: When you are planning the location of the modules, start to mount them in a height
that makes it easy to reach the handsets and to read the handsets' display.
Measure and mark the drill holes by using the dimensions in
the Rack PDM Charger on the wall with four screws.
Figure 4. Mounting dimensions in mm. Rack PDM Charger seen from the back.

2.1.4 ELECTRICAL INSTALLATION

Power Supply by Power Cord to Wall Outlet
The Rack PDM Charger is delivered with a cord with an IEC C14 connector (male). An
extension cord IEC C13 AC connector (female, IEC60320-C13) to wall socket has to
be ordered separately. It shall be connected between the pre-installed AC connector
(male) and the wall socket.
Figure 5. Rack PDM Charger with IEC C14 connector and an extension cord with an
21/1531-ANF 901 43 F 2017-04-25
figure